Measurement mapping for ETL
This table describes the suggested mappings for supported EBO values:
|
Descriptive Name |
Unit Name |
Unit Symbol |
Suggested Mappings |
|---|---|---|---|
| Absolute voltage in dB | |||
|
|
dBuV | ||
| AbsoluteHumidityMass | |||
|
kg/kg |
|||
|
lb/lb |
|||
| Acceleration | |||
|
meters per second squared |
m/s² |
||
|
feet per second squared |
ft/s² |
||
|
inches per second squared |
in/s² |
||
| Acidity | |||
| pH | |||
| Angle | |||
|
radian |
rad |
|
|
|
|
deg |
Fundamental Current Angle A |
|
|
|
grad |
|
|
| Angular momentum | |||
|
joule second |
Js |
||
| Area | |||
|
square meter |
m² |
||
|
square inch |
in² |
||
|
square foot |
ft² |
||
|
square yard |
yd² |
||
|
acre |
a. |
||
|
square mile |
mile² |
||
| Capacitance | |||
|
farad |
F |
||
| Compressibility | |||
|
meters squared per Newton |
m²/N |
||
| Conductance | |||
|
siemens |
S |
||
| Conductivity | |||
|
siemens per meter |
S/m |
||
| Corrosion Rate | |||
|
m/yr |
|||
|
in/yr |
|||
| Currency | |||
|
currency1 |
Energy Cost |
||
|
currency2 |
|
||
|
currency3 |
|
||
|
currency4 |
|
||
|
currency5 |
|
||
|
currency6 |
|
||
|
currency7 |
|
||
|
currency8 |
|
||
|
currency9 |
|
||
|
currency10 |
|
||
| Current | |||
|
A |
Current Phase Average |
||
| Current Density | |||
|
A/m² |
Current Density (A/m^2) |
||
| Density | |||
|
grams per cubic meter |
g/m³ |
||
|
pounds per cubic inch |
lb/in³ |
||
|
pounds per cubic foot |
lb/ft³ |
||
| Diffusivity | |||
|
meters squared per second |
m²/s |
||
|
foot squared per second |
ft²/s |
||
| Dipole Moment | |||
|
debye |
|||
|
coulombmeter |
|||
| Electrical Field Strength | |||
| V/m | |||
| Energy | |||
|
J |
|
||
|
Wh |
Active Energy Delivered (kWh) |
||
|
Btu |
Water Heat Flow (BTU 59) |
||
|
cal |
|
||
|
thermal |
|
||
|
tonh |
|
||
| Energy Apparent | |||
|
Vah |
Apparent Energy Received (KVAh) |
||
| Energy Reactive | |||
|
Varh |
Reactive Energy Delivered (kvarh) |
||
| Enthalpy | |||
|
J/kg |
Specific Enthalpy (J/kg) |
||
|
Btu/lb |
Specific Enthalpy (BTU 59/lb av) |
||
|
Enthalpy Dry Air |
|||
|
J/kg dry air |
Specific Enthalpy Dry Air (J/kg) |
||
|
Btu/lb dry air |
Specific Enthalpy Dry Air (BTU 59/lb av) |
||
| Entropy | |||
| J/K | |||
| Flow | |||
|
cubic meters per second |
m³/s |
Steam Volume Flow Rate (m^3/s) |
|
|
cubic meters per minute |
m³/min |
Steam Volume Flow Rate (m^3/min) |
|
|
cubic meters per hour |
m³/h |
Steam Volume Flow Rate (m^3/h) |
|
|
cubic feet per second |
ft³/s |
Steam Volume Flow Rate(cf/s) |
|
|
cubic feet per minute |
ft³/min |
Steam Volume Flow Rate(cf/min) |
|
|
cubic feet per hour |
ft³/h |
Steam Volume Flow Rate(cf/h) |
|
|
gallons per second |
Usgal/s |
Water Volume Flow Rate Supply (gal/s) |
|
|
gallons per minute |
Usgal/min |
Water Volume Flow Rate Return (gal/min) |
|
|
gallons per hour |
Usgal/h |
Water Volume Flow Rate Supply (gal/h) |
|
|
liters per second |
l/s |
Water Volume Flow Rate Supply (L/s) |
|
|
liters per minute |
l/min |
Water Volume Flow Rate Supply (L/min) |
|
|
liters per hour |
l/h |
Water Volume Flow Rate Supply (L/h) |
|
|
|
liq oz/s |
Water Volume Flow Rate Supply (fl oz imp/s) |
|
|
imperial gallons per minute |
Ukgal/min |
Water Volume Flow Rate Supply (gal imp/min) |
|
| Flow Rate Mass | |||
|
g/s |
|||
|
lb/s |
|||
|
oz/s |
|||
|
g/min |
|||
|
g/h |
|||
|
lb/min |
|||
|
Uston/h |
|||
| Force | |||
|
N |
|||
|
lbf |
|||
| Frequency | |||
|
Hz |
Frequency (Hz) |
||
|
cycles/min |
|
||
|
cycles/h |
|
||
|
/s |
|
||
|
/min |
|
||
|
/h |
|
||
|
%/s |
|
||
| Grammage (GSM) | |||
|
g/m² |
Grammage (GSM) (g/m²) |
||
| Heat Capacity | |||
|
J/(g·C) |
Specific Heat Capacity (J/(g deg C)) |
||
|
Btu/(lb·F) |
Specific Heat Capacity (BTU 59/(lb av deg F)) |
||
| Heat Degree Days | |||
|
°Cdays |
Heating Degree Days Celsius |
||
|
°Fdays |
Heating Degree Days Fahrenheit |
||
| Heat Flux | |||
|
W/m² |
|||
|
Btu/(s·ft²) |
|||
|
W/ft² |
|||
| Heat Transfer Coefficient | |||
|
W/(m²·K) |
Heat Transfer Coefficient (W/(m^2 K)) |
||
|
Btu/(s·ft²·K) |
Heat Transfer Coefficient (BTU 59/(s ft^2 K)) |
||
| Humidity | |||
|
% Rh |
Relative Humidity (Hour Interval) |
||
| Illuminance | |||
|
lux |
lx |
Illuminance (lx) |
|
|
|
ft·cd |
|
|
|
Candelas per sq. meter |
H |
Illuminance (H) |
|
| Inductance | |||
|
henry |
H |
||
| Length | |||
|
meter |
m |
||
|
inch |
in |
||
|
foot |
ft |
||
|
yard |
yd |
||
|
mile |
mile |
||
|
Linear Momentum |
|||
| Newton Second | Ns | ||
|
Luminance |
|||
| candelas per square meter | cd/m² | ||
|
Luminous Flux |
|||
| lm | |||
|
Luminous Intensity |
|||
| cd | |||
|
Magnetic Dipole Moment |
|||
| A·m² | |||
|
Magnetic Field Strength |
|||
| A/m | |||
|
Magnetic Flux |
|||
| Wb | |||
|
Magnetic Flux Density |
|||
|
|
T | ||
| Mass | |||
|
gram |
g |
||
|
pound |
lb |
||
|
ounce |
oz |
||
|
|
carat |
||
|
|
grains |
||
|
|
USTon |
||
| Mass Transfer Coefficient | |||
|
(mol/(s·m²))/ (mol/m³) |
|||
|
(mol/(s·ft²))/ (mol/ft³) |
|||
| Mass Velocity | |||
|
g/(s·m²) |
|||
|
lb/(s·ft²) |
|||
|
Moles |
|||
|
|
mole |
mol |
|
|
|
lbmol |
||
|
Moment of Inertia |
|||
|
|
|
g/m² |
|
|
lb/ft² |
|||
|
Momentum |
|||
|
|
|
g·m/s |
|
|
lb·ft/s |
|||
|
NoCategory |
|||
|
|
|
NoUnit |
|
|
? |
|||
| Percent Obscuration | |||
|
|
|
%/m |
|
|
|
|
%/ft |
|
|
Percentage |
|||
|
|
|
% |
Damper Position (percent) |
|
|
|
ppm |
CO₂ Concentration Indoor (ppm) |
|
|
|
ppb |
|
| Phase | |||
| deg | |||
| Power | |||
|
W |
Active Power Phase B (kW) |
||
|
VA |
Apparent Power Phase A (KVA) |
||
|
Btu/s |
|
||
|
hp |
|
||
|
Btu/h |
Water Heat Flow Rate (BTU 59/h) |
||
|
tons refrig |
|
||
| Power Factor | |||
|
cosf |
Power Factor Signed Phase A |
||
| Power Reactive | |||
|
var |
Reactive Power Phase A (kvar) |
||
| Pressure | |||
|
N/m² |
Air Pressure (N/m^2) |
||
|
Pa |
Air Pressure (Pa) |
||
|
psi |
Air Pressure psi Natural Gas Pressure (psi) |
||
|
mHg |
Air Pressure (m Hg) |
||
|
inH₂0 |
Air Pressure (in H2O) |
||
|
bar |
Air Pressure (bar) |
||
|
mH₂0 |
Air Pressure (m H2O) |
||
|
inHg |
Air Pressure (in Hg) |
||
|
db (SPL) |
Sound Pressure Level (dB) |
||
| Pressure Drop Per Length | |||
|
Pa/m |
Air Pressure Drop Per Length (Pa/m) |
||
|
psi/ft |
Air Pressure Drop Per Length (psi/ft) |
||
| Resistance | |||
|
ohm |
Ω |
Resistance |
|
| Resistivity | |||
|
ohm meter |
Ωm |
||
| Specific Entropy | |||
|
J(g·K) |
|||
|
Btu/(lb·R) |
|||
|
J/(kg·K) |
|||
| Specific Humidity | |||
| g H₂0/kg dry air | |||
| Specific Volume | |||
|
m³/g |
|||
|
ft³/lb |
|||
|
Surface Energy Density |
|||
|
J/m² |
|||
|
J/ft² |
|||
|
W/(h·m²) |
|||
|
W/(h·ft²) |
|||
| Surface Tension | |||
|
N/m² |
|||
|
lbf/ft |
|||
| Temperature | |||
|
°C |
Weather Temperature CelsiusWater Temperature (deg C) |
||
|
K |
|
||
|
°F |
Weather Temperature Fahrenheit Water Temperature (deg F) |
||
|
Temperature Diff |
|||
|
Δ°C |
Weather Temperature Differential (deg C) |
||
|
ΔK |
|
||
|
Δ°F |
Weather Temperature Differential (deg F) |
||
| Temperature Rate of Change | |||
|
°C/min |
Air Temperature Mixed Rate of Change (deg C/min) |
||
|
K/min |
|
||
|
°F/min |
Air Temperature Mixed Rate of Change (deg F/min) |
||
|
°C/h |
Air Temperature Mixed Rate of Change (deg C/h) |
||
|
K/h |
|
||
|
°F/h |
Air Temperature Mixed Rate of Change (deg F/h) |
||
| Thermal Conductance | |||
|
W/(m²·K) |
|||
| Thermal Conductivity | |||
|
W/(m²·K/m) |
Air Thermal Conductivity (W/(m K)) |
||
|
Btu/(h·ft²·F/ft) |
Air Thermal Conductivity (BTU 59/(h ft deg F)) |
||
| Thermal Linear Expansion | |||
|
m/C |
|||
|
in/F |
|||
|
ft/F |
|||
| Thermal Pressure | |||
| psi/oF | |||
| Thermal Volume Expansion | |||
|
m³/C |
|||
|
in³/F |
|||
|
ft³/F |
|||
| Thermoelectric Power | |||
| V/K | |||
| Time | |||
|
year |
|||
|
month |
|||
|
week |
|||
|
day |
|||
|
h |
|||
|
min |
|||
|
s |
|||
| Time Accuracy | |||
| s/h | |||
| Torque | |||
|
Nm |
|||
|
lbf·in |
|||
|
lbf·ft |
|||
| Turbidity | |||
| NTU | |||
| Velocity | |||
|
m/s |
Air Velocity (m/s) |
||
|
m/h |
Air Velocity (m/h) |
||
|
mile/h |
Air Velocity (mile/h) |
||
|
ft/s |
Air Velocity (ft/s) |
||
|
ft/min |
Air Velocity (ft/min) |
||
|
m/min |
Air Velocity (m/min) |
||
| Velocity Angular | |||
|
radians per second |
rad/s |
||
|
revolutions per minute |
RPM |
||
| Voltage | |||
|
V |
Average Voltage Line-to-Neutral |
||
| Volume | |||
|
m³ |
Air Volume (m^3) |
||
|
in³ |
|
||
|
ft³ |
Air Volume (cubft) |
||
|
Usgal |
Wastewater Volume (gal) |
||
|
litre |
Wastewater Volume (L) |
||