The
view is where you display your scene and its constituent assemblies and loads. You can also graphically visualize what happens when you play the scene.The three arrows in the middle represent the 3-D coordinate system of the Information About the Coordinate System.
view using the colors X = red, Y = green, Z = blue. For further information, refer toSelect an object in the
view and perform the following mouse actions for rotation around the different axes:
Mouse Action |
Rotation around axis |
---|---|
Scroll the mouse wheel |
Z |
Hold down the key and scroll the mouse wheel |
Y |
Hold down the key and scroll the mouse wheel |
X |
By default, the
view contains one section. The section is the container of assemblies inside a scene. The default section has a size of 50,000 mm x 50,000 mm and can be modified in the view. The floor of the section is displayed gray by default but if you flip the scene to see it from below the floor appears transparent. In the view, the floor can be modified regarding color and type.To add sections to the
view, proceed as follows:
Step |
Action |
---|---|
1 |
In the view, right-click the node and execute the command from the contextual menu.Results:
|
2 |
In the view, select the node of the new section, to make it active.Result: Further information on the section is displayed in the view. |
You can modify what is displayed as the floor in the
view by modifying the properties of the section. Proceed as follows:
Step |
Action |
---|---|
1 |
In the view, expand the node and select the node. |
2 |
In the view, modify the properties. |
With the parameter
you can assign a name to the section that is displayed at the lower right corner of the floor in the view.To hide the selected section from the
view, deselect the check box .Enter the
and of your choice to modify the size of the section.Enter the
and / or the (in °) to modify the position of the section in space (in a cartesian coordinate system).Select an option from
to move, lock, enable or select assemblies in the selected section.Select another option from
to modify, for example, the color or the texture of the section displayed as floor.In *.dxf or *.dwg file.
, you can, for example, hide the grid and enable bounds or you can import a floor design of your choice by selecting the option and importing aThe properties defined here are specific to the selected section. When you open a new
view, a default section with the default settings opens.The status bar at the bottom of the
view displays information about the scene:
Column |
Description |
---|---|
/ |
Indicates if the time is running (the scene is playing) or paused. |
|
Indicates the time (in ms) it took to calculate the last step of the physical simulation. If this number becomes too high, an advisory message will be displayed on the right-hand side of this status bar. |
Lock icon |
Indicates whether the scene is locked. |
Time displayed as [dd:hh:mm:ss] |
Displays the time elapsed while playing the scene. |
Time scale |
Displays the time scale for playing the scene, such as: = real time = double real time The maximum is times real time. |
Information and diagnostic messages |
Provides information and advisory messages that are relevant while playing the scene. The messages are color-coded according to the severity. For information on messages provided in the Logs View. view, refer to the chapter |