FUNCTION_BLOCK DTCProvider EXTENDS CBM.LTrig IMPLEMENTS IDTCProvider
This function block is used in conjunction with DM1_Write or DM2_Write function blocks. It serves as data provider for diagnostic trouble codes. One or more DTCProvider can be connected to one DMx_Write function block. A DTC will be activated by setting xEnable to TRUE.
InOut:
|
Scope |
Name |
Type |
Comment |
Inherited from |
|
Input |
xEnable |
BOOL |
TRUE: Action starts FALSE: Action stops, outputs xDone, xBusy, xError are resetted |
LTrig |
|
Output |
xDone |
BOOL |
TRUE: Action successfully completed |
LTrig |
|
xBusy |
BOOL |
TRUE: Function block active |
LTrig |
|
|
xError |
BOOL |
TRUE: Error occurred, function block aborts action FALSE: No error |
LTrig |
|
|
Input |
itfDTCProviderList |
IDTCProviderList |
DMx_Write instance |
|
|
Data |
DTC data |
|||
|
Output |
eError |
detailed error information if xError is true. |