Removal of the Optional Module (No Replacement)
Required Tool for Removal of the Optional Module (no Replacement)
Module part |
Tool |
---|---|
Module shaft |
Cross slot maximum PH1 |
How to Disassemble the Optional Module
Step |
Action |
---|---|
1 |
Set main switch to OFF position, or otherwise disconnect all power to the system. |
2 |
Prevent main switch from being switched back on. |
3 |
Undo the two M3x6 screws on the module shaft. |
4 |
Withdraw the module from the cartridge. Result: The module is deinstalled now and the module shaft is empty. |
5 |
Screw the blanking plate onto the empty module shaft. Result: The empty module shaft is closed by the blanking plate. |
NOTICE |
INOPERABLE EQUIPMENT |
Do not remove the optional module when the controller is under power. |
Failure to follow these instructions can result in equipment damage. |