Message MS1400: The selected motion profile does not match the selected load profile. The load profile must have the same x offset, cycle time, x min and x max as the motion profile.

Overview

Message ID

Message description

Message type

MS1400

The selected motion profile does not match the selected load profile. The load profile must have the same x offset, cycle time, x min and x max as the motion profile.

Information

Cause of the Message

The motion profile and the load diagram selected for the mechanics of your machine application do not match. The values for the parameters x offset, Cycle time as well as the X value for start and end points of a segment must be identical in both profiles.

Effect

Motion Sizer calculations do not lead to usable results if the values differ between load and motion.

Solution

Verify the values for x offset, Cycle time as well as the X value for start and end points you defined for the Cam and the load diagrams and adapt them.

Select a load case that corresponds to the motion profile when you define the mechanic of your machine application.