FC_WriteToFile

 

FC_WriteToFile - General Information

Overview

Type:

Function

Available as of:

SystemInterface_1.32.6.0

Versions:

Current version

Task

Write the number of bytes in a file.

Description

The function writes the number (i_diCount) of bytes from a variable (i_pbyVarAdr) into the file identified by i_diFileId.

NOTE: The processing time of this function is a few hundred milliseconds. This is why the times for the cycle check of the task in which this function is performed should be increased one-time. For example FC_CycleCheckTimeSet(500, 2).

Interface

Input

Data type

Description

i_diFileId

DINT

Name of the file to be written

i_pbyVarAdr

POINTER TO BYTE

Variable where the write data is stored

i_diCount

DINT

Number of bytes to be written

Return Value

Data type

Description

DINT

0: OK

-3: Incorrect FileId (< 1000000 or >1000009)

-5: File is not open