FC_CopyExceptionDelayList - General Information
Type: |
Function |
Available as of: |
V1.0.4.0 |
A copy of the exception list with delayed reactions is created to display it in an HMI or to perform own evaluations.
The function copies the ExceptionDelayList. It creates an array from the internal display of the ExceptionDelayList (linked list). The list is only copied when it has changed. Communication in the exception list is achieved here using the functions that manipulate the list via the xExceptionDelayListHasChanged variable. As a result, the entries for the time remaining until the exceptions become active (todElapsedTime) are not updated. If these time stamps are relevant to the user, copying must always be forced by setting the i_xForceCopy input to TRUE.
Input |
Data type |
Description |
---|---|---|
i_xCopy |
BOOL |
Copying of the data when the list has changed. |
i_xForceCopy |
BOOL |
Forces copying of the data even if the list has not changed. To this end, i_xCopy must also be set to TRUE. |
Output |
Data type |
Description |
---|---|---|
q_etDiag |
General, library-independent statement on the diagnostic. A value unequal GD.ET_Diag.Ok equates an error message. |
|
q_etDiagExt |
POU-specific output on the diagnostic. q_etDiag = GD.ET_Diag.Ok -> status message q_etDiag <> GD.ET_Diag.Ok -> diagnostic message |
Input/Output |
Data type |
Description |
---|---|---|
iq_stExceptionList |
Exception list from which the list of exceptions with delayed reactions shall be copied. |
|
iq_astException |
ARRAY[1..Gc_udiMaxNumberOfDelay] OF ST_Exception |
Array into which the list shall be copied to. |
iq_udiNumberOfExceptions |
UDINT |
Number of exceptions that were entered into the array. |
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
---|---|---|---|
OK |
85 |
The ExceptionDelayList has been copied |
|
OK |
86 |
There are no changes in exception delay list |
|
OK |
50 |
Waiting for copy job |
|
UnexpectedProgramBehavior |
87 |
The ExceptionDelayList is damaged. The list must be created again. |
|
UnexpectedProgramBehavior |
46 |
Initialization of the exception list failed. |
Enumeration name: |
ExceptionDelayListCopied |
Enumeration value: |
85 |
Description: |
The ExceptionDelayList has been copied |
The exception list with delayed reactions has been copied.
Enumeration name: |
ExceptionDelayListCorrupt |
Enumeration value: |
87 |
Description: |
The ExceptionDelayList is damaged. The list must be created again. |
Issue |
Cause |
Solution |
---|---|---|
- |
The exception list with delayed reactions is damaged. |
Please inform the support team about this error. |
Enumeration name: |
ExceptionDelayListNoChange |
Enumeration value: |
86 |
Description: |
There are no changes in exception delay list |
The list of exceptions with delayed reactions has not changed since the last copying.
Enumeration name: |
InitExceptionListFailed |
Enumeration value: |
46 |
Description: |
Initialization of the exception list failed. |
Issue |
Cause |
Solution |
---|---|---|
- |
Initialization of the exception list failed. - An internal execution error occured. |
Try to initialize the exception list using the FC_InitExceptionList function. Please inform the support team about this error. |
Enumeration name: |
WaitForCopy |
Enumeration value: |
50 |
Description: |
Waiting for copy job |
The function waits for i_xCopy = TRUE before it copies the list of exceptions with delayed reactions.