ZeroTrackStart

General

Type

EF

Devices supporting the parameter

Incremental Encoder Input

Traceable

Yes

Functional Description

Enables the zero track detection.

A rising edge of this parameter (switch-over from false / 0 -> true / 1) activates the zero track detection on the incremental encoder input. Zero Track detection evaluates the level of the incremental encoder's zero track.

Value

Data type

Meaning

false / 0

BOOL

Zero track detection disabled.

true / 1

BOOL

Zero track detection enabled.

NOTE: When a zero track occurs, the HW immediately sets the internal increment counter to 0. In the next Sercos cycle, Position and Velocity are corrected.

This can be ignored when you are using the zero track as a reference. When you are using the zero track for a highly cyclic activity, the slight deviation in velocity can cause the position to deviate.

The position results from the current counter status.

Velocity is taken from the previous velocity since the current value is not available. As a result, the position derived from the velocity is slightly inaccurate.