UserData[0]...[3]

General

Type

AD

Devices supporting the parameter

Encoder network (Synchronization master and Synchronization slave)

Traceable

Yes

Functional Description

Displays user-specific encoder network data.

Synchronization encoder output

By using the Synchronization encoder input, user-specific data can be sent via the encoder network to the Synchronization encoder inputs. These data are displayed by all syncs. Encoder inputs with the same delay (parameter DataDelay) as the encoder data. For this purpose, 16 bytes are available which can either be written as separate UDINT values using the parameters UserData[0] ... UserData[3] or consistently via the function FC_SyncWriteDataOutUserData().

Synchronization encoder input

UserData[0] ... UserData[3] display the user-specific data of the sync. encoder output. The function FC_SyncReadDataInUserData() is available for consistent reading.