Type |
EF (only online editable) |
Offline editable |
No |
Devices supporting the parameter |
PacDrive LMC x00C, PacDrive LMC x01C, Lexium LXM52 Drive, Lexium LXM52 Linear Drive, Lexium LXM62 Drive, Lexium LXM62 Linear Drive, Lexium ILM62 Drive Module, DIO8 module, OnBoard I/O, Lexium LXM62 Power Supply, Sercos Drive, Sercos I/O, TM5CSLCx00FS, Bus Interface TM5NS31, Analog input, COM, Virt. Master Encoder, SinCos Encoder Input, Incremental Encoder Input, Log. encoder, Sum encoder, Sum encoder input, Sum Master Encoder, Sum master encoder input, Encoder network (Synchronization master, Synchronization encoder output, Sync. Module, Synchronization encoder input, and Synchronization slave), Cam Switch Group, Cam Track, Cam Switch, Uninterruptable Power Supply, PacNet, bus terminals BT-4/DIO1, BT-4/DIO1 TP, and BT-4/ENC1, C2C Master, C2C Slave, C2C Data Input, C2C Data Output, C2C Encoder Input, C2C Encoder Output, Logic Motion Controller Device, Machine Encoder Input |
Traceable |
No |
Displays the name specified in the Devices tree. This name can be modified dynamically in the program.
The name is used in the following functions / parameters:
oMessage logger (names in the column Instance)
Transfer time: loading the message logger
oCam Track (parameter PositionSource)
Transfer time: parameter Enable FALSE -> TRUE
oLogical encoder (parameter InObject)
Transfer time: FC_SetMasterEncoder()
oIncremental Encoder Output (parameter InObject)
Transfer time: FC_SetMasterEncoder()
oSum master encoder input (parameter InObject)
Transfer time: FC_SetMasterEncoder()
oSum encoder input (parameter InObject)
Transfer time: FC_SetMasterEncoder()
oFC_GetObjInstanceLogAdrByName()
oFC_GetObjLogAdrByName()
oFC_GetObjNameByLogAdr()
oC2C Encoder Output (parameter InObject)
Transfer time: FC_SetMasterEncoder()
oC2C Online View tab of the C2C Master (names in the column Devices)
For the functions and parameters mentioned, use the active name at the time of execution.