Type |
ER |
Devices supporting the parameter |
PacDrive LMC x00C, PacDrive LMC x01C |
Traceable: |
Yes |
Automatic program start after creating the control voltage.
NOTE: This parameter is a reset parameter (ER). Changes will take effect only after a reset of the controller. To save the values as initialization values after changing the value of the parameter via online change or in the application, the function FC_SysSaveParameter has to be called.
The presetting for AutoRun = FALSE.
While preparing the application and during commissioning, AutoRun must be set to false.
|
UNINTENDED STARTUP |
Use appropriate safety interlocks where personnel and/or equipment hazards exist. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
During regular machine operation the parameter AutoRun = TRUE. Otherwise the start of the application can only take place via Logic Builder.
Value |
Data type |
Meaning |
---|---|---|
no / 0 |
BOOL |
No automatic program start |
yes / 1 |
BOOL |
Automatic program start after booting the PacDrive controller |