Type |
EF |
Devices supporting the parameter |
PacDrive LMC x00C, PacDrive LMC x01C |
Traceable |
Yes |
Using this parameter, you can reserve some addresses for the manual configuration of slave devices.
Value |
Data type |
Meaning |
---|---|---|
0 (default) |
UINT |
Number of addresses that shall be reserved for the manual configuration of slave devices. Also see parameter IPConfigMode. For this purpose, you have to set the parameter to a value greater than or equal to the number of slaves which are to be configured manually. Access type: read/write |
While a value for this parameter is being entered, it is checked whether the entered value lies within the value range of 0-1007.
NOTE: If a Safe Logic Controller (SLC) is added to a Sercos III bus, the current value of StaticAddressCount automatically increases by 1. Thus, the value of StaticAddressCount is automatically decreased by 1 if a Safe Logic Controller was deleted from a Sercos III bus.