Smart Fan Control automatically adjusts the fan speed so that they run faster when the CPU is hotter to maintain the CPU at a constant temperature without running the fan constantly.
This normally involves setting a minimum and maximum fan speed, as well as a high and low CPU temperature. At the low temperature, the fans start running at the minimum fan speed. The fan speed varies in line with the CPU temperature until it reaches the high CPU temperature.
BIOS Configuration for the Rack iPC Performance
|
Step |
Action |
|---|---|
|
1 |
For enter BIOS setup, press DEL or F2 key after the Rack iPC has been initialized. Use arrow keys to select among the items and press <Enter> to accept or enter the submenu. For creating the smart fan configuration use the BIOS Advanced menu:
|
|
2 |
Move to the Advanced settings and scroll down to the H/W Monitor: Select Smart Fan Mode Configuration and press Enter:
You can access the following options from the BIOS setup: oCPU Fan oSystem Front Fan oSystem Rear Fan |
|
3 |
Choose the fan and select Enable:
|
|
4 |
Move to the Advanced settings and Save and Exit. |
BIOS Configuration for the Rack iPC Universal and Optimized
|
Step |
Action |
|---|---|
|
1 |
For enter BIOS setup, press DEL or F2 key after the Rack iPC has been initialized. Use arrow keys to select among the items and press <Enter> to accept or enter the submenu. |
|
2 |
Move to the Advanced settings and scroll down to the H/W Monitor:
|
|
3 |
Move down to: oCPUFAN1 Mode Setting and change it to Enabled. oSYSFAN1 Mode Setting and change it to Enabled |
|
4 |
Move to the Advanced settings and Save and Exit. |