EcoStruxure Machine Expert version 1.1 does not support the M258, LMC058 and LMC078 controllers.

Other Distributed Devices

Encoder

OsiCoder (OsiSense XCC offer) is a range of rotary encoders.

Absolute multiturn encoders can be connected to CANopen for absolute position and speed reading.

Radio Frequency Identification Devices (RFID) Station

OsiSense XG Ethernet smart antenna is a compact RFID station offering the following advantages:

oread/write operations on most 13.56 MHz RFID tags on the market, such as ISO 14443 and ISO 15693 standard tags

odual Ethernet port for daisy chaining up to 32 smart antennas

oAn embedded web server allowing:

osetup

odiagnostic

omonitoring

ocommunication to logic controllers via Modbus TCP or EtherNet/IP

oprotection degrees IP65 and IK02

Vision Sensor

The OsiSense XUW vision sensor allows checking of high rate production operations with a high repeat accuracy. It can be used to manage object flows.

It covers the following application for manufactured parts:

oquality control

opresence

oposition, orientation, sorting, integrity

ochecking markings

oguiding and gripping

 

The OsiSense XUW vision sensor offers the following advantages:

oresolution: 736 x 480 pixels (WVGA)

o4 to 10 outputs / 2 to 6 inputs, PNP or NPN

ocommunication to logic controllers via EtherNet/IP

oprotection degree IP65 or IP67 depending on connection

Safety Controller XPSMC

Preventa XPSMC is a range of configurable safety controllers:

o16 and 32 input versions

o4 (2 x 2 NO) relay outputs and 6 solid-state outputs

o30 certified safety functions in order to respond to specific application requirements

oNon-safety-related communication to controllers via Modbus, CANopen, or PROFIBUS.

The XPSMC configurable safety controllers are certified by TÜV Nord meeting the requirements of category 4, PL e according to EN ISO 13849-1 and up to SILCL 3 according to IEC/EN 60261.

Modular Safety Controller XPSMCM

The Preventa XPSMCM Modular Safety Controller system is composed of

oa logic controller which can be configured using the SoSafe Configurable software

oSafety-related I/O expansion modules

oSafety-related speed monitoring modules

oSafety-related communication expansion modules for island creation

oNon-safety-related communication modules with fieldbus interface

 

The XPSMCM system provides flexibility and scalability

oup to 14 expansion modules and therefore up to 128 safety-related inputs and 16 safety-related outputs

oup to 6 decentralized safety-related I/O island with a distance of 50 meters (164 ft.) per island on one controller

o10 different fieldbus expansion modules for non-safety-related communication with logic controllers

The XPSMCM system is certified by TÜV Süd meeting the requirements of category 4, PL e according to EN ISO 13849-1 up to SIL 3 according to IEC/EN 61508 and up to SILCL 3 according to IEC/EN 60261.

NOTE: The preconfigured EtherNet/IP device Preventa XPSMCM provided in the EcoStruxure Machine Expert device repository is compatible with the default configuration of the fieldbus expansion module XPSMCMCO000•EI with firmware ≥ V1.8. In case you use an earlier version, contact your local Schneider Electric representative.

Push Button

Harmony XB5R wireless and batteryless push buttons are used for remote control with an access point.