EcoStruxure Machine Expert version 1.1 does not support the M258, LMC058 and LMC078 controllers.

PacDrive LMC Eco Motion Controllers

 

PacDrive LMC Eco

Overview

Software configuration and hardware description can be found in the following manuals:

oPacDrive LMC Eco Device Objects and Parameters

oPacDrive LMC Eco Motion Controller - Hardware Guide

The Schneider Electric PacDrive LMC Eco is a controller with various powerful features. It can control a wide range of applications. The PacDrive LMC Eco combines both logic controller and motion functions.

PacDrive LMC Eco controllers synchronize, coordinate, and create the motion functions of a machine for a maximum of:

o0 Sercos servo drives for the controller PacDrive LMC100C

o4 Sercos servo drives for the controller PacDrive LMC101C

o6 Sercos servo drives for the controller PacDrive LMC106C

o8 Sercos servo drives for the controller PacDrive LMC201C

o12 Sercos servo drives for the controller PacDrive LMC212C

o16 Sercos servo drives for the controller PacDrive LMC216C

Key Features

The EcoStruxure Machine Expert software compatible with the controller provides the following IEC 61131-3 programming languages:

oIL: Instruction List

oST: Structured Text

oFBD: Function Block Diagram

oSFC: Sequential Function Chart

oLD: Ladder Diagram

EcoStruxure Machine Expert software can also be used to program the controller using CFC (Continuous Function Chart) language.

The PacDrive LMC Eco supports the following fieldbuses:

oIntegrated automation bus Sercos (master)

oIntegrated additional fieldbus CAN (master / slave)

oOptional slot for additional fieldbus

The PacDrive LMC Eco supports the following I/O types:

oMaster encoder input

oEmbedded I/Os:

oDigital I/Os

oAdvanced digital inputs (touch probe and interrupt inputs)

oDistributed I/O modules on Sercos automation bus (TM5 modules)