The Online > Create boot application command allows you to create a controller application that is automatically started after it has been downloaded from the EcoStruxure Machine Expert PC to the controller.
NOTE: This function is restricted to controller applications. HMI applications do not support this feature.
The boot application automatically will be stored as <applicationname>.app on the controller.
Step |
Action |
---|---|
1 |
In the Applications tree, select the Application node of the application you want to create a boot application for. |
2 |
From the Online menu, select the command Create boot application. Result: EcoStruxure Machine Expert will automatically build the application. If errors are detected during the build process, they will be issued in the Messages view. If the build process is executed successfully, a Save as dialog box will be displayed. |
3 |
In the Save as dialog box, navigate to the folder where you want to save the boot application and click the Save button. Result: A message box will be displayed asking you whether you want to overwrite the reference context of the last download. |
4 |
Click Yes and the following files will be saved to the specified folder: oMyapplication.App oMyapplication.crc |
You can now transfer these files to your controller. For further information, refer to the documentation of your controller.