Adding Devices by Drag and Drop
Adding Devices by Drag and Drop
EcoStruxure Machine Expert provides a multi-tabbed catalog view on the right-hand side of the EcoStruxure Machine Expert Logic Builder.
Two different types of catalog views are available:
oThe Hardware Catalog
oThe Software Catalog
To add a device to the Devices tree, select the respective entry in the Hardware Catalog, drag it to the Devices tree, and drop it at a suitable node. It is added automatically to your project.
Adding Controllers by Drag and Drop
Step |
Action |
---|---|
1 |
Open the Hardware Catalog by clicking the Hardware Catalog button |
2 |
Select the tab Controller in the Hardware Catalog. Result: The controllers suitable for your EcoStruxure Machine Expert project are displayed in the Hardware Catalog. |
3 |
Select a controller entry in the Controller tab, drag it to the Devices tree and drop it at a suitable node. You can drop a controller at any empty space inside the Devices tree. Result: The controller is added to the Devices tree as a new node with different subnodes depending on the controller type. |
Adding Expansion Devices by Drag and Drop
Step |
Action |
---|---|
1 |
Open the Hardware Catalog by clicking the Hardware Catalog button |
2 |
Select the tab Devices & Modules in the Hardware Catalog. Result: The expansion devices suitable for your EcoStruxure Machine Expert project are displayed in the Hardware Catalog. |
3 |
Select your expansion device, drag it to the Devices tree and drop it at a suitable subnode of a controller. NOTE: Suitable subnodes are expanded and highlighted by EcoStruxure Machine Expert. Result: The expansion device is added to the Devices tree below the subnode of the controller. |
4 |
If the expansion device requires a communication manager, this node is added automatically to the Devices tree. If several communication managers are available for your expansion device, a dialog box is displayed allowing you to select the suitable communication manager. |
Adding Devices and Modules by Drag and Drop
Step |
Action |
---|---|
1 |
Open the Hardware Catalog by clicking the Hardware Catalog button |
2 |
Select the tab Devices & Modules in the Hardware Catalog. Result: The field devices suitable for your EcoStruxure Machine Expert project are displayed in the Hardware Catalog. |
3 |
Select a field device entry in the Devices & Modules catalog view, drag it to the Devices tree, and drop it at a suitable subnode of a controller. NOTE: Suitable subnodes are expanded and highlighted by EcoStruxure Machine Expert. Result: The field device is added to the Devices tree below the subnode of the controller. |
4 |
If the field device requires a communication manager, this node is added automatically to the Devices tree. If several communication managers are available for your field device, a dialog box is displayed allowing you to select the suitable communication manager. |
Adding Devices from Device Template by Drag and Drop
Step |
Action |
---|---|
1 |
Open the Hardware Catalog by clicking the Hardware Catalog button |
2 |
Select the tab Devices & Modules in the Hardware Catalog. |
3 |
Select the option Device Template at the bottom of the Devices & Modules tab. Result: The device templates suitable for your EcoStruxure Machine Expert project are displayed in the Devices & Modules tab. |
4 |
Add them to the Devices tree as described in the Adding Devices from Template chapter. |
Adding Devices from Function Template by Drag and Drop
Step |
Action |
---|---|
1 |
Open the software catalog by clicking the Software Catalog button |
2 |
Select the tab Macro in the Software Catalog. Result: The function templates available in EcoStruxure Machine Expert are displayed in the Software Catalog. |
3 |
Select a function template entry in the Macro view, drag it to the Devices tree, and drop it at a suitable subnode of a controller. NOTE: Suitable subnodes are expanded and highlighted by EcoStruxure Machine Expert. Result: The device based on the function template is added to the Devices tree. |