About the Modicon M218 Logic Controller
Modicon M218 Logic Controller Devices Overview
The Schneider Electric Modicon M218 Logic Controller has a variety of powerful features. This Controller can service a wide range of applications.
The software configuration and programming is accomplished with the EcoStruxure Machine Expert software, and is described in the EcoStruxure Machine Expert Programming Guide.
Programming languages
The Modicon M218 Logic Controller is supported and programmed with the EcoStruxure Machine Expert software, which supports the following IEC61131-3 programming languages:
oST: Structured Text
oFBD: Function Block Diagram
oSFC: Sequential Function Chart
EcoStruxure Machine Expert software can also be used to program these controllers using CFC (Continuous Function Chart) language.
The power supply of the Modicon M218 Logic Controller is either: 24 Vdc or 100...240 Vac, depending on the controller model.
The Modicon M218 Logic Controller includes a Real Time Clock (RTC) system.
1 Run/Stop switch is integrated on each controller to toggle its state.
Memory
The table below describes the different types of memory:
|
Memory type |
Size |
Used |
|---|---|---|
|
RAM |
1 Mbytes |
To execute the application. |
|
Flash |
1 Mbytes |
To save program and data in case of a power interruption. |
Embedded Input/Output
The following embedded I/O types are available, depending on the controller model:
oRegular input
oFast input (HSC)
oRegular output
Embedded Communication features
3 types of communication ports are available on the front panel, depending on the controller model:
oEthernet Port (for TM218LDAE24DRHN and TM218LDAE40DRPHN)
oUSB Programming Port
o2 Serial Link Port
For more details, refer to the chapter Integrated Communication Ports.
Modicon M218 Logic Controller Range
|
Reference |
Digital Input |
Digital Output |
Analog Input |
Analog Output |
|---|---|---|---|---|
|
7 regular inputs and 2 fast inputs (HSC)(1) |
7 relay outputs |
No |
No |
|
|
12 regular inputs and 2 fast inputs (HSC)(1) |
10 relay outputs |
No |
No |
|
|
10 regular inputs and 4 fast inputs (HSC) (2) |
10 relay outputs |
No |
No |
|
|
10 regular inputs and 4 fast inputs (HSC)(2) |
6 regular outputs and 4 fast outputs (PTO/PWM/FG)(3) |
No |
No |
|
|
10 regular inputs and 4 fast inputs (HSC)(2) |
10 relay outputs |
No |
No |
|
|
22 regular inputs and 2 fast inputs (HSC)(1) |
16 relay outputs |
No |
No |
|
|
20 regular inputs and 4 fast inputs (HSC)(2) |
12 relay outputs and 4 fast outputs (PTO/PWM/FG)(3) |
No |
No |
|
|
20 regular inputs and 4 fast inputs (HSC)(2) |
12 regular outputs, and 4 fast outputs (PTO/PWM/FG)(3) |
No |
No |
|
|
20 regular inputs and 4 fast inputs (HSC)(2) |
12 relay outputs and 4 fast outputs (PTO/PWM/FG)(3) |
No |
No |
|
|
20 regular inputs and 4 fast inputs (HSC)(2) |
16 relay outputs |
No |
2 analog outputs |
|
|
20 regular inputs and 4 fast inputs (HSC)(2) |
12 relay outputs and 4 fast outputs (PTO/PWM/FG)(3) |
2 analog inputs |
2 analog outputs |
|
|
34 regular inputs and 2 fast inputs (HSC)(1) |
24 relay outputs |
No |
No |
|
|
(1) The reduced fast inputs have a maximum frequency of 10 kHz. They can be used either as regular inputs or as reduced fast inputs for counting. (2) The fast inputs can be used either as regular inputs or as fast inputs for counting or event functions. (3) The fast outputs can be used either as regular outputs or as fast outputs for PTO, PWM, Frequency Generator functions, or reflex output for HSC. |
||||