Exporting/Importing .semdt Files
Machine Assistant allows you to export your project when using EcoStruxure Machine Expert or to export the scan results when using the Web Server. You can import the scan results from the Web Server in an empty project in EcoStruxure Machine Expert. You can also import a project from EcoStruxure Machine Expert to the Web Server. You can compare the configured devices to the scanned devices.
Step |
Action |
|
---|---|---|
1 |
Click the scan button to scan the connected devices. |
|
2 |
Click the Export scan results button |
|
3 |
Save the .semdt file in your PC. Result: Your project and the detected devices during the scan are exported. |
Step |
Action |
|
---|---|---|
1 |
Open your project in offline mode. |
|
2 |
Click the scan button to scan your project. |
|
3 |
Click the Export configuration as semdt file button. |
|
4 |
Save the .semdt file on your PC. Result: Your project is exported. |
The load .semdt file button allows you to upload a project in EcoStruxure Machine Expert or scanned devices in the Web Server.