Diagnostics of the Sercos Master
Diagnostics via the Sercos LED
The LED S3 provides information on diagnostics related to Sercos.
![]()
|
LED color |
Description |
---|---|---|
![]()
|
Off |
State NRT (no Sercos communication) |
![]()
|
Orange |
Communication phase is CP0, CP1, CP2 or CP3 |
![]()
|
Green |
Communication phase is CP4 |
![]()
|
Red |
State error |
If an error is detected, remove the cause of the detected error. After that, use the parameter DesiredPhase of the parameter group SercosPhaseChanger to set the master to the communication state NRT and then back to the required communication phase.
Use the parameter IDN S-0-0390 (Diagnostic Number) to read diagnostics information from the Sercos slaves.
Additional Information in Loggers
The CODESYS Logger and the Message Logger provide additional messages. Refer to these logger entries for information regarding troubleshooting, commissioning, and diagnostics.