The motors are equipped with a SinCos encoder. The drive can access the electronic nameplate via the Hiperface interface for commissioning.
The signals meet the PELV requirements.
This motor encoder measures an absolute value within one revolution at start-up and continues to count incrementally from this point.
|
Characteristic |
Value |
|---|---|
|
Resolution in increments |
Depending on evaluation |
|
Resolution per revolution |
128 sin/cos periods |
|
Measuring range absolute |
1 revolution |
|
Accuracy of the digital absolute value1) |
±0.0889° |
|
Accuracy of the incremental position |
±0.0222° |
|
Signal shape |
Sinusoidal |
|
Supply voltage |
7 ... 12 Vdc |
|
Maximum supply current |
60 mA (without load) |
|
Maximum angular acceleration |
200000 rad/s2 |
|
1) Depending on the evaluation through the drive, the accuracy may be increased by including the incremental position in the calculation of the absolute value. In this case, the accuracy corresponds to the incremental position. |
|
This motor encoder measures an absolute value within 4096 revolutions at start-up and continues to count incrementally from this point.
|
Characteristic |
Value |
|---|---|
|
Resolution in increments |
Depending on evaluation |
|
Resolution per revolution |
128 sin/cos periods |
|
Measuring range absolute |
4096 revolutions |
|
Accuracy of the digital absolute value1) |
±0.0889° |
|
Accuracy of the incremental position |
±0.0222° |
|
Signal shape |
Sinusoidal |
|
Supply voltage |
7 ... 12 Vdc |
|
Maximum supply current |
60 mA (without load) |
|
Maximum angular acceleration |
200000 rad/s2 |
|
1) Depending on the evaluation through the drive, the accuracy may be increased by including the incremental position in the calculation of the absolute value. In this case, the accuracy corresponds to the incremental position. |
|
This motor encoder measures an absolute value within one revolution at start-up and continues to count incrementally from this point.
|
Characteristic |
Value |
|---|---|
|
Resolution in increments |
Depending on evaluation |
|
Resolution per revolution |
16 sin/cos periods |
|
Measuring range absolute |
1 revolution |
|
Accuracy of position |
± 0.08° |
|
Signal shape |
Sinusoidal |
|
Supply voltage |
7 ... 12 Vdc |
|
Maximum supply current |
50 mA (without load) |
This motor encoder measures an absolute value within 4096 revolutions at start-up and continues to count incrementally from this point.
|
Characteristic |
Value |
|---|---|
|
Resolution in increments |
Depending on evaluation |
|
Resolution per revolution |
16 sin/cos periods |
|
Measuring range absolute |
4096 revolutions |
|
Accuracy of position |
± 0.08° |
|
Signal shape |
Sinusoidal |
|
Supply voltage |
7 ... 12 Vdc |
|
Maximum supply current |
50 mA (without load) |