Setting the Parameters

Overview

The parameters to be set are available in the following folders of the Parameters tab:

oIdentification

oGeneral

oMotor/Mechanic

oRealtimechannel

Setting the Identification Parameters

Parameter

Value

Description/Comment

IdentificationMode

Depending on the required system setup.

The ATV340S supports the settings TopologyAddress and SercosAddress.

For details, refer to the description of the IdentificationMode parameter in the Device Objects and Parameters Guide of your PacDrive LMC Eco controller or PacDrive LMC Pro/Pro2 controller.

ConfigurationVendorCode

1

Mandatory setting

ConfiguredVendorDeviceID

ATV340S

Mandatory setting

Setting the General Parameters

Parameter

Value

Description/Comment

UserMaxVel

Align the values with the drive setup.

-

UserMaxAcc

ControllerStopDec

ControllerStopJerk

StopDec

MotorPeakC

ControllerPeakC

Setting the Motor/Mechanic Parameters

Parameter

Value

Description/Comment

FeedConstant

60

Mandatory setting

FeedbackResolution

131072

Mandatory setting

MaxRPM

Align the value with the drive setup.

-

ModuloValue

0

Mandatory setting

Setting the Realtimechannel Parameters

Parameter

Value

Description/Comment

TelegrammType

7

Mandatory setting

ConfigurationListAT

'S-0-0051.0.0'

Position, mandatory setting

ConfigurationListMDT

'S-0-0047.0.0'

RefPosition, mandatory setting

NOTE:

You can add 9 additional parameters to each configuration list.

oConfigurationListAT: S-0-0051.0.0 (Position) - mandatory; optional up to 9 parameters (refer to the parameters list)

oConfigurationListMDT: S-0-0047.0.0 (RefPosition) - mandatory; optional up to 9 parameters (refer to the parameters list)