Replacement Equipment of the Lexium EAC1-Series
The following replacement equipment and accessories are listed:
For detailed information about appropriate accessories for the Lexium EAC1-Series, refer to the accessories in the catalog Unimotion PNCE Electric Cylinder .
To order the respective accessories, contact your local Schneider Electric service representative.
For detailed information about an appropriate belt drive for the Lexium EAC1-Series, refer to the motor side drives in the catalog Unimotion PNCE Electric Cylinder .
To order the respective belt drive, contact your local Schneider Electric service representative.
The clamping set consists of self-locking devices and belt pulleys.
To order the respective clamping set, contact your local Schneider Electric service representative.
The elastomer coupling consists of two clamping hubs and one elastomer spider.
For detailed information about an appropriate elastomer coupling for the Lexium EAC1-Series, refer to the couplings in the catalog Unimotion PNCE Electric Cylinder .
To order the respective elastomer coupling, contact your local Schneider Electric service representative.
Order data
|
Representation |
Description |
Actuator |
Characteristic feature |
Order number |
|---|---|---|---|---|
|
For lubricating the actuator. Volume: 120 cm3 (7.3 in3); delivery volume: 0.5 cm3 (0.03 in3) / stroke: o1x single-hand lubrication gun |
All |
Grease |
VW33MAP01 |
NOTE: The single-hand lubrication gun is empty. Furthermore, a nozzle pipe is required for lubrication.
For detailed information about appropriate motors for the Lexium EAC1-Series, contact your local Schneider Electric service representative.
Order data
|
Representation |
Description |
Actuator |
Characteristic feature |
Order number |
|---|---|---|---|---|
|
For extending the lubrication gun: o1x nozzle pipe Suitable for lubrication nipple type D6. |
All |
Pointed nozzle 90° lateral |
VW33MAT01 |
|
Pointed nozzle 20° angled |
VW33MAT02 |
For detailed information about appropriate sensors for the Lexium EAC1-Series, refer to the sensors in the catalog Unimotion PNCE Electric Cylinder .
To order the respective sensors, contact your local Schneider Electric service representative.
For detailed information about appropriate sensor holders for the Lexium EAC1-Series, refer to the sensor holders in the catalog Unimotion PNCE Electric Cylinder .
To order the respective sensor holders, contact your local Schneider Electric service representative.
Order data
|
Representation |
Description |
For sensor contact type |
Length in m (ft) |
Order number |
|---|---|---|---|---|
|
For extending the sensor cable: o1x sensor extension cable Suitable for drag chain applications; sensor side end 3-pin M8 circular connector, second cable end is open. |
PNP, normally closed PNP, normally open |
5 (16.4) |
VW32SBCBGA050 |
|
10 (33) |
VW32SBCBGA100 |
|||
|
20 (66) |
VW32SBCBGA200 |
To order the appropriate toothed belt, contact your local Schneider Electric service representative.