NOTE: Regrind the holding brake if a motor was stored for over 2 years before mounting.
Step |
Action |
---|---|
1 |
Observe the Prerequisites for Replacing Components and Cables and the special measures for Replacement of the Lexium 62 ILM. |
2 |
Set main switch to OFF position to free system of voltage. |
3 |
Prevent main switch from being switched back on. |
4 |
Disconnect the connection cables on the motor. |
5 |
Loosen the screw connections on the motor. Result: The motor is removed from the machine and disconnected from the electrical supply lines. |
How to Regrind the Holding Brake
NOTE: The motor must not be installed in machine and the holding brake must be engaged.
|
UNINTENDED AXIS MOVEMENTS |
Only grind the holding brake when the removed motor is disconnected from the electrical supply lines. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
Step |
Action |
---|---|
1 |
Verify the holding torque of the holding brake using a torque wrench. |
2 |
Compare the value to the specified holding torque of the holding brake upon delivery. |
3 |
If the holding torque of the holding brake considerably differs from the specified values, manually rotate the motor shaft by 25 rotations in both directions. |
4 |
Repeat the process. If you cannot restore the original holding torque after repeating the process 3 times, contact your Schneider Electric representative. |