The maintenance intervals may have to be adapted to the greatly varying operational hours depending on the application.
For procedures to replace the different parts, refer to Replacing Parts.
Interval |
Action |
---|---|
Every 150 hours of operation or weekly |
oVerify the robot by visual inspection for any damage or missing parts, especially moving parts and parts at risk for collisions such as grippers, upper arms, lower arms, parallel plate, or parallel linkage rods. oReplace the arms or the parallel linkage rods if these are bent or dented. oClean the robot mechanics. |
Every 1,000 hours of operation or every three months |
oVerify all moving parts for bolted connections. oVerify the output shaft sealing of gearboxes for deposits of dirt and clean. |
Every 3,000 hours of operation or every six months |
oVerify the arm bearings and replace them if necessary. oVerify the parallel plate bearings and replace them if necessary. |
Annually |
oVerify the parallel rod system and replace or lubricate the ball ends of the parallel rods with a grease gun if necessary. oVerify the brake function during operation. |
Every 20,000 hours of operation |
oReplace the main gearboxes and motors. |
Every 40,000 hours of operation |
oReplace the upper arms. |
Every 1,000 emergency stop situations |
oReplace the upper arms. |
NOTE: The gearbox and the bearings have been lubricated for life.