Power Stage Data - Drive-Specific

Data for Single-Phase Devices at 115 Vac

Characteristic

Unit

Value

LXM32•U45M2

LXM32•U90M2

LXM32•D18M2

LXM32•D30M2

Nominal voltage (single-phase)

Vac

115

115

115

115

Inrush current limitation

A

1.7

3.5

8

16

Maximum fuse to be connected upstream(1)

A

25

25

25

25

Continuous output current

Arms

1.5

3

6

10

Peak output current

Arms

3

6

10

15

Minimum inductance motor (phase/phase)

mH

5.5

3

1.4

0.8

Values without mains reactor(2)

Nominal power

kW

0.15

0.3

0.5

0.8

Input current(3)

Arms

2.9

5.4

8.5

12.9

THD (total harmonic distortion)(4)

%

173

159

147

135

Power dissipation(5)

W

7

15

28

33

Maximum inrush current(6)

A

111

161

203

231

Time for maximum inrush current

ms

0.8

1.0

1.2

1.4

Values with mains reactor

Mains reactor

mH

5

2

2

2

Nominal power

kW

0.2

0.4

0.8

0.8

Input current(3)

Arms

2.6

5.2

9.9

9.9

THD (total harmonic distortion)(4)

%

85

90

74

72

Power dissipation(5)

W

8

16

32

33

Maximum inrush current(6)

A

22

48

56

61

Time for maximum inrush current

ms

3.3

3.1

3.5

3.7

(1) As per IEC 60269. Circuit breakers with B or C characteristic. See chapter Conditions for UL 508C and CSA for UL and CSA. Lower ratings are permissible. The fuse must be rated in such a way that the fuse does not trip at the specified input current.

(2) At a mains impedance corresponding to a short-circuit current of the supply mains of 1 kA

(3) At nominal power and nominal voltage

(4) With reference to the input current

(5) Condition: internal braking resistor not active. Value at nominal current, nominal voltage and nominal power. Value approximately proportional with output current.

(6) Extreme case, off/on pulse before the inrush current limitation responds, see next line for maximum time

Data for Single-Phase Devices at 230 Vac

Characteristic

Unit

Value

LXM32•U45M2

LXM32•U90M2

LXM32•D18M2

LXM32•D30M2

Nominal voltage (single-phase)

Vac

230

230

230

230

Inrush current limitation

A

3.5

6.9

16

33

Maximum fuse to be connected upstream(1)

A

25

25

25

25

Continuous output current

Arms

1.5

3

6

10

Peak output current

Arms

4.5

9

18

30

Minimum inductance motor (phase/phase)

mH

5.5

3

1.4

0.8

Values without mains reactor(2)

Nominal power

kW

0.3

0.5

1.0

1.6

Input current(3)

Arms

2.9

4.5

8.4

12.7

THD (total harmonic distortion)(4)

%

181

166

148

135

Power dissipation(5)

W

10

18

34

38

Maximum inrush current(6)

A

142

197

240

270

Time for maximum inrush current

ms

1.1

1.5

1.8

2.1

Values with mains reactor

Mains reactor

mH

5

2

2

2

Nominal power

kW

0.5

0.9

1.6

2.2

Input current(3)

Arms

3.4

6.3

10.6

14.1

THD (total harmonic distortion)(4)

%

100

107

93

86

Power dissipation(5)

W

11

20

38

42

Maximum inrush current(6)

A

42

90

106

116

Time for maximum inrush current

ms

3.5

3.2

3.6

4.0

(1) As per IEC 60269. Circuit breakers with B or C characteristic. See chapter Conditions for UL 508C and CSA for UL and CSA. Lower ratings are permissible. The fuse must be rated in such a way that the fuse does not trip at the specified input current.

(2) At a mains impedance corresponding to a short-circuit current of the supply mains of 1 kA

(3) At nominal power and nominal voltage

(4) With reference to the input current

(5) Condition: internal braking resistor not active. Value at nominal current, nominal voltage and nominal power. Value approximately proportional with output current.

(6) Extreme case, off/on pulse before the inrush current limitation responds, see next line for maximum time

Data for Three-Phase Devices at 208 Vac

Characteristic

Unit

Value

LXM32•U60N4

LXM32•D12N4

LXM32•D18N4

LXM32•D30N4

LXM32•D72N4

Nominal voltage (three-phase)

Vac

208

208

208

208

208

Inrush current limitation

A

2.2

4.9

10

10

29

Maximum fuse to be connected upstream(1)

A

32

32

32

32

32

Continuous output current

Arms

1.5

3

6

10

24

Peak output current

Arms

6

12

18

30

72

Minimum inductance motor (phase/phase)

mH

8.5

4.5

3

1.7

0.7

Values without mains reactor(2)

Nominal power

kW

0.35

0.7

1.2

2.0

5

Input current(3)

Arms

1.8

3.6

6.2

9.8

21.9

THD (total harmonic distortion)(4)

%

132

136

140

128

106

Power dissipation(5)

W

13

26

48

81

204

Maximum inrush current(6)

A

60

180

276

341

500

Time for maximum inrush current

ms

0.5

0.7

0.9

1.1

1.5

Values with mains reactor

Mains reactor

mH

2

2

1

1

1

Nominal power

kW

0.4

0.8

1.5

2.6

6.5

Input current(3)

Arms

1.7

3.1

6.0

9.2

21.1

THD (total harmonic distortion)(4)

%

97

79

78

59

34

Power dissipation(5)

W

13

27

51

86

218

Maximum inrush current(6)

A

19

55

104

126

155

Time for maximum inrush current

ms

1.9

2.6

2.6

3.0

3.6

(1) As per IEC 60269. Circuit breakers with B or C characteristic. See chapter Conditions for UL 508C and CSA for UL and CSA. Lower ratings are permissible. The fuse must be rated in such a way that the fuse does not trip at the specified input current.

(2) At a mains impedance corresponding to a short-circuit current of the supply mains of 5 kA

(3) At nominal power and nominal voltage

(4) With reference to the input current

(5) Condition: internal braking resistor not active. Value at nominal current, nominal voltage and nominal power. Value approximately proportional with output current.

(6) Extreme case, off/on pulse before the inrush current limitation responds, see next line for maximum time

Data for Three-Phase Devices at 400 Vac

Characteristic

Unit

Value

LXM32•U60N4

LXM32•D12N4

LXM32•D18N4

LXM32•D30N4

LXM32•D72N4

Nominal voltage (three-phase)

Vac

400

400

400

400

400

Inrush current limitation

A

4.3

9.4

19

19

57

Maximum fuse to be connected upstream(1)

A

32

32

32

32

32

Continuous output current

Arms

1.5

3

6

10

24

Peak output current

Arms

6

12

18

30

72

Minimum inductance motor (phase/phase)

mH

8.5

4.5

3

1.7

0.7

Values without mains reactor(2)

Nominal power

kW

0.4

0.9

1.8

3.0

7

Input current(3)

Arms

1.4

2.9

5.2

8.3

17.3

THD (total harmonic distortion)(4)

%

191

177

161

148

126

Power dissipation(5)

W

17

37

68

115

283

Maximum inrush current(6)

A

90

131

201

248

359

Time for maximum inrush current

ms

0.5

0.7

0.9

1.1

1.4

Values with mains reactor

Mains reactor

mH

2

2

1

1

1

Nominal power

kW

0.8

1.6

3.3

5.6

13

Input current(3)

Arms

1.8

3.4

6.9

11.1

22.5

THD (total harmonic distortion)(4)

%

108

90

90

77

45

Power dissipation(5)

W

19

40

74

125

308

Maximum inrush current(6)

A

28

36

75

87

112

Time for maximum inrush current

ms

1.9

2.3

2.3

2.6

3.0

(1) As per IEC 60269. Circuit breakers with B or C characteristic. See chapter Conditions for UL 508C and CSA for UL and CSA. Lower ratings are permissible. The fuse must be rated in such a way that the fuse does not trip at the specified input current.

(2) At a mains impedance corresponding to a short-circuit current of the supply mains of 5 kA

(3) At nominal power and nominal voltage

(4) With reference to the input current

(5) Condition: internal braking resistor not active. Value at nominal current, nominal voltage and nominal power. Value approximately proportional with output current.

(6) Extreme case, off/on pulse before the inrush current limitation responds, see next line for maximum time

Data for Three-Phase Devices at 480 Vac

Characteristic

Unit

Value

LXM32•U60N4

LXM32•D12N4

LXM32•D18N4

LXM32•D30N4

LXM32•D72N4

Nominal voltage (three-phase)

Vac

480

480

480

480

480

Inrush current limitation

A

5.1

11.3

23

23

68

Maximum fuse to be connected upstream(1)

A

32

32

32

32

32

Continuous output current

Arms

1.5

3

6

10

24

Peak output current

Arms

6

12

18

30

72

Minimum inductance motor (phase/phase)

mH

8.5

4.5

3

1.7

0.7

Values without mains reactor(2)

Nominal power

kW

0.4

0.9

1.8

3.0

7

Input current(3)

Arms

1.2

2.4

4.5

7.0

14.6

THD (total harmonic distortion)(4)

%

201

182

165

152

129

Power dissipation(5)

W

20

42

76

129

315

Maximum inrush current(6)

A

129

188

286

350

504

Time for maximum inrush current

ms

0.6

0.7

1.0

1.2

1.6

Values with mains reactor

Mains reactor

mH

2

2

1

1

1

Nominal power

kW

0.8

1.6

3.3

5.6

13

Input current(3)

Arms

1.6

2.9

6.0

9.6

19.5

THD (total harmonic distortion)(4)

%

116

98

98

85

55

Power dissipation(5)

W

21

44

82

137

341

Maximum inrush current(6)

A

43

57

116

137

177

Time for maximum inrush current

ms

1.9

2.4

2.4

2.7

3.2

(1) As per IEC 60269. Circuit breakers with B or C characteristic. See chapter Conditions for UL 508C and CSA for UL and CSA. Lower ratings are permissible. The fuse must be rated in such a way that the fuse does not trip at the specified input current.

(2) At a mains impedance corresponding to a short-circuit current of the supply mains of 5 kA

(3) At nominal power and nominal voltage

(4) With reference to the input current

(5) Condition: internal braking resistor not active. Value at nominal current, nominal voltage and nominal power. Value approximately proportional with output current.

(6) Extreme case, off/on pulse before the inrush current limitation responds, see next line for maximum time