8521 Sercos C2C configuration

Description

Refer to Diagnostic class (standard): 1

This diagnostic message contains additional information on diagnostic message 8520 Sercos C2C misconfiguration detected.

The extended diagnostic describes which parameter caused the diagnostic message:

Ext. diagnosis

Meaning

ID=

ID of the data object with a duplicate ID. This diagnostic message is set for each duplicate data object detected from diagnostic message 8520 Sercos C2C misconfiguration detected duplicate ID.

Typ=

The type of the data object that caused the diagnostic message8520 Sercos C2C misconfiguration detected Type mismatch.

Len=

The data size of the data object that caused the diagnostic message 8520 Sercos C2C misconfiguration detected Type mismatch.

DataT=

The type of the data object that caused the diagnostic message 8520 Sercos C2C misconfiguration detected DataT mismatch.