ET_DiagExt

 

ET_DiagExt - General Information

Overview

Type:

Enumeration type

Available as of:

V 1.0.0.0

Versions:

Current version

Description

The enumeration ET_DiagExt specifies the POU-specific diagnostic and status messages.

Enumeration Elements

Name

Value

Description

Ok

0

Status message.

CmdUnknown

1

Indeterminable command.

CmdImpossibleState

2

The command cannot be executed in the state.

InitFailed

4

Initialization failed

ExceptionListOverflow

6

Overflow of the exception list

InsertExceptionInList

7

An exception is currently being entered into the exception list.

DeleteExceptionFromList

8

This message is triggered if an exception is being deleted from the list.

AsyncStopActive

9

Indicates that ET_StandardReaction.AsyncStop is active.

SyncStopElActive

10

Indicates that ET_StandardReaction.SyncStopEl is active.

SyncStopEhActive

11

Indicates that ET_StandardReaction.SyncStopEh is active.

StopEndOfCycleActive

12

Indicates that ET_StandardReaction.StopEndOfCycle is active.

CmdImpossibleReaction

13

The command cannot be executed due to a pending reaction.

CmdImpossibleOverwrite

14

The command cannot be overwritten.

Held

15

Indicates that the EDESIGN module is currently in the state Held.

Unholding

16

Indicates that the EDESIGN module is currently in the state Unholding.

Holding

17

Indicates that the EDESIGN module is currently in the state Holding.

Idle

18

Indicates that the EDESIGN module is currently in the state Idle.

Starting

19

Indicates that the EDESIGN module is currently in the state Starting.

Execute

20

Indicates that the EDESIGN module is currently in the state Execute.

Completing

21

Indicates that the EDESIGN module is currently in the state Completing.

Complete

22

Indicates that the EDESIGN module is currently in the state Complete.

Resetting

23

Indicates that the EDESIGN module is currently in the state Resetting.

UnSuspending

24

Indicates that the EDESIGN module is currently in the state UnSuspending.

Suspended

25

Indicates that the EDESIGN module is currently in the state Suspended.

Suspending

26

Indicates that the EDESIGN module is currently in the state Suspending.

Stopped

27

Indicates that the EDESIGN module is currently in the state Stopped.

Stopping

28

Indicates that the EDESIGN module is currently in the state Stopping.

Clearing

29

Indicates that the EDESIGN module is currently in the state Clearing.

Aborted

30

Indicates that the EDESIGN module is currently in the state Aborted.

Aborting

31

Indicates that the EDESIGN module is currently in the state Aborting.

SystemFatalException

32

A Diagnostic class 4 error has been detected on the controller.

SystemException

33

A Diagnostic class 3 error has been detected on the controller.

SystemWarning

34

A Diagnostic class 2 or 1 error has been detected on the controller.

UserReactionActive

35

Indicates that the UserReaction is active.

Disabled

36

The POU is disabled.

Initializing

37

Initialization

WaitForMainsOn

38

Waiting for MainsOn

MainsWatchException

39

Exception while monitoring the mains contactor

WaitUntilPowerOnDelayExpired

40

Waiting until switch-on delay has elapsed.

WaitUntilExceptionIsReset

41

Waiting until exception has been reset.

ControllerInvalid

42

The controller is not supported.

CheckMainsWatch

43

Checking the mains contactor.

PowerOn

44

The mains contactor is switched on.

PointerDiagDataInvalid

45

Pointer to DiagData invalid

NameOfDiagSourceNotUnique

47

Name of DiagSource not unique

WaitForDiagnosticsConnected

48

Wait until connection to PacDrive Diagnostics

DiagnosticsConnectionInterrupted

49

Diagnostics connection interrupted

EchoCommandProcessed

50

Echo command processed

CouldNotOpenFile

51

Could not open the file

UnexpectedFeedback

52

Unexpected feedback

MaxNumberOfDiagSourcesExceeded

53

Maximum number of DiagSources exceeded

ListOfDataElementsRequested

54

List of data elements requested

DiagSourceIdInvalid

55

DiagSource invalid

RamDiskFull

56

Ramdisk is full

DataFromDiagSourceRequested

57

Requested data from DiagSource

ContinueGettingDataOfDiagSourceImpossible

58

Continuing getting data of DiagSource impossible

CouldNotCloseFile

59

Could not close the file

FileIdInvalid

60

File Id is invalid

WaitUntilDiagnosticsManagerReady

69

Wait until DiagnosticsManager ready

WaitUntilDisabled

70

Wait until disabled

WaitUntilDiagSourceRegistered

71

Wait until DiagSource is registered

WaitForCommunication

72

Waiting for communication

DataSuccessfullyWritten

73

Data successfully written

WritingToFile

74

Writing to file

HeaderColumnIdInvalid

82

Id of header column is invalid

UnknownDiagExt

95

Unknown DiagExt message

PointerSubModuleInvalid

96

Pointer to Submodule invalid

PointerFirstMiniDiagSourceInvalid

97

Pointer to FirstMiniDiagSource invalid

FirstMiniDiagSourceInitFailed

98

Initialization of first MiniDiagSource failed

SubsequentMiniDiagSourceInitFailed

99

Initialization of subsequent MiniDiagSource failed