FB_MultiBeltModuleController - General Information
|
Type: |
Function block |
|
Available as of: |
V1.0.4.0 |
|
Versions: |
Current version |
Managing jogging jobs of all modules of type TPL.ET_ModuleType.MultiBeltModule in one node.
Jogging jobs of the inputs i_xJogForw and i_xJogBack of the StandardMotionInterface are forwarded to the module axes selected via i_axDriveSelect. If an exception is active in the exception list, all jogging jobs are canceled. If the Sercos leaves phase 4, i_xResetHomeOk of all modules is set.
|
Input |
Data type |
Description |
|---|---|---|
|
i_xEnable |
BOOL |
A rising edge FALSE -> TRUE activates the POU, a falling edge TRUE -> FALSE deactivates the POU. A deactivated POU does not execute any actions. |
|
Output |
Data type |
Description |
|---|---|---|
|
q_xActive |
BOOL |
TRUE: The POU is active and has to be executed further. FALSE: The POU is inactive. |
|
q_xReady |
BOOL |
TRUE: The POU is ready to operate and can accept user commands. FALSE: The function block is not ready to accept user commands. |
|
q_etDiag |
General library-independent statement on the diagnostic. A value unequal to GD.ET_Diag.Ok corresponds to a diagnostic message. |
|
|
q_etDiagExt |
POU-specific output on the diagnostic. q_etDiag = GD.ET_Diag.Ok -> status message q_etDiag <> GD.ET_Diag.Ok -> diagnostic message |
|
|
q_sMsg |
STRING[80] |
Event-triggered message which gives more detailed information on the diagnostic state. |
|
Input/Output |
Data type |
Description |
|---|---|---|
|
iq_stStandardModuleItf |
The StandardModuleInterface of the node in which the controller is integrated. |
|
|
iq_stStandardMotionItf |
The StandardMotionInterface of the node in which the controller is integrated. |
|
|
iq_stExceptionList |
The exception list of the node in which the controller is integrated. |
|
|
iq_stLogDataList |
The logger list of the node in which the controller is integrated. |
|
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
|---|---|---|---|
|
OK |
29 |
The POU is disabled. |
|
|
OK |
21 |
The operation is being executed. |
|
|
InputParameterInvalid |
26 |
The additional interface has not been correctly initialized. |
|
|
SercosConditionInvalid |
27 |
The G_ifSercos interface is invalid. |
|
Enumeration name: |
Disabled |
|
Enumeration value: |
29 |
|
Description: |
The POU is disabled. |
The function block is disabled and executes no actions whatsoever. i_xEnable and q_xActive are set to FALSE
|
Enumeration name: |
GlobalSercosInterfaceInvalid |
|
Enumeration value: |
27 |
|
Description: |
The G_ifSercos interface is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
The global Sercos interface G_ifSercos is invalid. |
Ensure that the Sercos interface G_ifSercos outside the function block is not accidentally overwritten with 0. |
|
Enumeration name: |
MissingExtInit |
|
Enumeration value: |
26 |
|
Description: |
The additional interface has not been correctly initialized. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
The initialization of the additional interfaces Ext is unavailable. |
Ensure that interfaces of the modules are initialized. Ensure that the FC_UpdateAddInterfaceStruct function is called up for axis modules. |
|
Enumeration name: |
Operation |
|
Enumeration value: |
21 |
|
Description: |
The operation is being executed. |
The controller manages the data of the MultiBeltModule.