FB_MultiBeltModuleController

 

FB_MultiBeltModuleController - General Information

Overview

Type:

Function block

Available as of:

V1.0.4.0

Versions:

Current version

Task

Managing jogging jobs of all modules of type TPL.ET_ModuleType.MultiBeltModule in one node.

Description

Jogging jobs of the inputs i_xJogForw and i_xJogBack of the StandardMotionInterface are forwarded to the module axes selected via i_axDriveSelect. If an exception is active in the exception list, all jogging jobs are canceled. If the Sercos leaves phase 4, i_xResetHomeOk of all modules is set.

Interface

Input

Data type

Description

i_xEnable

BOOL

A rising edge FALSE -> TRUE activates the POU, a falling edge TRUE -> FALSE deactivates the POU.

A deactivated POU does not execute any actions.

Output

Data type

Description

q_xActive

BOOL

TRUE: The POU is active and has to be executed further.

FALSE: The POU is inactive.

q_xReady

BOOL

TRUE: The POU is ready to operate and can accept user commands.

FALSE: The function block is not ready to accept user commands.

q_etDiag

GD.ET_Diag

General library-independent statement on the diagnostic.

A value unequal to GD.ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = GD.ET_Diag.Ok -> status message

q_etDiag <> GD.ET_Diag.Ok -> diagnostic message

q_sMsg

STRING[80]

Event-triggered message which gives more detailed information on the diagnostic state.

Input/Output

Data type

Description

iq_stStandardModuleItf

TPL.ST_StandardModuleInterface

The StandardModuleInterface of the node in which the controller is integrated.

iq_stStandardMotionItf

TPL.ST_StandardMotionInterface

The StandardMotionInterface of the node in which the controller is integrated.

iq_stExceptionList

TPL.ST_ExceptionList

The exception list of the node in which the controller is integrated.

iq_stLogDataList

TPL.ST_LogDataList

The logger list of the node in which the controller is integrated.

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Disabled

29

The POU is disabled.

OK

Operation

21

The operation is being executed.

InputParameterInvalid

MissingExtInit

26

The additional interface has not been correctly initialized.

SercosConditionInvalid

GlobalSercosInterfaceInvalid

27

The G_ifSercos interface is invalid.

Disabled

Enumeration name:

Disabled

Enumeration value:

29

Description:

The POU is disabled.

The function block is disabled and executes no actions whatsoever. i_xEnable and q_xActive are set to FALSE

GlobalSercosInterfaceInvalid

Enumeration name:

GlobalSercosInterfaceInvalid

Enumeration value:

27

Description:

The G_ifSercos interface is invalid.

Issue

Cause

Solution

-

The global Sercos interface G_ifSercos is invalid.

Ensure that the Sercos interface G_ifSercos outside the function block is not accidentally overwritten with 0.

MissingExtInit

Enumeration name:

MissingExtInit

Enumeration value:

26

Description:

The additional interface has not been correctly initialized.

Issue

Cause

Solution

-

The initialization of the additional interfaces Ext is unavailable.

Ensure that interfaces of the modules are initialized.

Ensure that the FC_UpdateAddInterfaceStruct function is called up for axis modules.

Operation

Enumeration name:

Operation

Enumeration value:

21

Description:

The operation is being executed.

The controller manages the data of the MultiBeltModule.