ET_StartMovementMode

 

ET_StartMovementMode - General Information

Overview

Type:

List type

Available as of:

V1.0.0.0

Description

This enumeration defines the movement behavior of the FB_Unwinder during the start phase.

Enumeration Elements

Name

Value

Description

None

0

No start movement. The unwinder immediately starts with a precontrol- and control movement.

MoveToRefPosition

1

At first the dancer is moved to its reference position. Afterwards the unwinder moves according to the precontrol- and control movement.

SpliceFromStandstill

2

The unwinder waits until the machine feeds the foil and then it accelerates the bobbin so that it moves the dancer to its reference position. Afterwards the unwinder moves according to the precontrol- and control movement.

Torque

3

The bobbin is moved with a fixed torque until i_lrStartThreshold is reached. Afterwards the unwinder moves according to precontrol and control movement.