Systemticks

General

Type

EF

Devices supporting the parameter

PacDrive LMC x00C, PacDrive LMC x01C

Traceable

No

Functional Description

NOTE: The system behaves differently! It is hard for users to predict how the behavior of the system changes. This parameter must only be changed after consulting the Schneider Electric application department.

Task change for tasks of the same priority per second. This is used to set the system cycle of the PacDrive controller. The default value of the system cycle for the controller is set to 250 µs. The resulting value for system ticks is 1/250 µs = 4000. The system cycle can be set to 50 µs.

NOTE: This parameter is a reset parameter (ER). Changes will take effect only after a reset of the controller. To save the values as initialization values after changing the value of the parameter via online change or in the application, the function FC_SysSaveParameter has to be called.