TYPE SMC_HOMING_MODE :
Defines the homing sequence. Used in function block SMC_Homing.
InOut:
|
Name |
Initial |
Comment |
|
0 |
Move with fast velocity onto the reference switch; invert and move with slow velocity out of the reference switch; execute “set position”; stop |
|
|
1 |
Move with fast velocity onto the reference switch; invert and move with slow velocity out of the reference switch; stop; execute “set position” |
|
|
2 |
Move with fast velocity onto the reference switch; invert and move with slow velocity out of the reference switch; wait for the index pulse; execute “set position”; stop |
|
|
4 |
Move with fast velocity onto the reference switch; move with slow velocity out of the reference switch; execute “set position”; stop |
|
|
5 |
Move with fast velocity onto the reference switch; move with slow velocity out of the reference switch; stop; execute “set position” |
|
|
6 |
Move with fast velocity onto the reference switch; move with slow velocity out of the reference switch; wait for the index pulse; execute “set position”; stop |