SR_<Conveyor Name> - General Information

Overview

Type:

Program

Available as of:

V2.1.1.0

This chapter provides information on:

oFunctional Description

oInterface in Case of Node Type 'PacDrive 3 Template'

oInterface in Case of Node Type 'Non Template'

oDiagnostic Messages

oProperties

oMethods

Functional Description

Smart Template Conveyor Module

G-SE-0078341.1.png

 

 

Interface in Case of Node Type 'PacDrive 3 Template'

Input/Output

Data type

Description

iq_stStandardModuleItf

TPL.ST_StandardModuleInterface

Standard module interface

iq_stExceptionList

TPL.ST_ExceptionList

Exception list

iq_stLogDataList

TPL.ST_LogDataList

Log data list

Interface in Case of Node Type 'Non Template'

Input

Data type

Description

i_xEnable

BOOL

A rising edge FALSE -> TRUE activates the POU, a falling edge TRUE -> FALSE deactivates the POU.

A deactivated POU does not execute any action.

i_xAsyncStop

BOOL

Initiate an immediate asynchronous stop. The process can no longer be accessed while the exception is pending. No commands can be executed while the reaction is pending. You may still execute certain special operating modes and commands required for exception elimination.

i_xSyncStopEL

BOOL

Initiate a synchronous stop (monitored by a timeout = waits until the movement stops). Deactivates the process after the synchronous stop has been completed. The process can no longer be accessed while the exception is pending. If the timeout (configurable) is triggered, the function transitions to an asynchronous stop.

i_xSyncStopEH

BOOL

Initiate a synchronous stop (monitored by a timeout = waits until the movement stops). Does NOT disable process after completion of the synchronous stop.

i_xStopEndOfCycle

BOOL

Initiate a stop at the end of the cycle. Does NOT deactivate the process.

i_xDiagQuit

BOOL

A rising edge FALSE -> TRUE cancels an active exception of the POU.

Output

Data type

Description

q_xActive

BOOL

TRUE: The POU is active. If the output is TRUE while the i_xEnable is deactivated, the POU must first terminate its ongoing processing before transitioning this output to FALSE.

FALSE: The POU is inactive

q_xReady

BOOL

TRUE: The POU is ready to operate and can accept user commands.

FALSE: The function block is not ready to accept user commands.

q_etDiag

GD.ET_Diag

General library-independent statement on the diagnostic. A value unequal to GD.ET_Diag.Ok corresponds to a diagnostic message.

q_udiDiagExt

UDINT

POU-specific output on the diagnostic.

q_etDiag = GD.ET_Diag.Ok -> Status message

q_etDiag <> GD.ET_Diag.Ok -> Diagnostic message

q_sDiagExt

STRING[80]

The name of the respective enumeration of q_udiDiagExt as Description.

q_sMsg

STRING[80]

Event-triggered message that gives more detailed information on the diagnostic state.

q_xException

BOOL

An error was detected and an exception is active.

q_xWarning

BOOL

An advisory is active.

q_etActiveOpMode

AXM.ET_OpMode

The active operating mode of the Smart Template conveyor module.

q_xCmdActive

BOOL

A command is active.

q_etCmdActive

AXM.ET_Cmd

The active command of the Smart Template conveyor module.

q_xCmdDone

BOOL

A command is terminated successfully.

q_xAsyncStop

BOOL

An immediate asynchronous stop is active. The process can no longer be accessed while the exception is pending. No commands can be executed while the reaction is pending. You may still execute certain special operating modes and commands required for exception elimination.

q_xSyncStopEL

BOOL

A synchronous stop (monitored by a timeout = waits until the movement stops) is active. Deactivates the process after the synchronous stop has been completed. The process can no longer be accessed while the exception is pending. If the timeout (configurable) is triggered, the function transitions to an asynchronous stop.

q_xSyncStopEH

BOOL

A synchronous stop (monitored by a timeout = waits until the movement stops) is active. Does NOT disable process after completion of the synchronous stop.

q_xStopEndOfCycle

BOOL

A stop at the end of the cycle is active. Does NOT deactivate the process.

Input/Output

Data type

Description

iq_etCmd

AXM.ET_Cmd

Transfer a module command to the module.

Diagnostic Messages

The diagnostic messages are identical to the AXM.FB_AxisModule.

Properties

Name

Data type

Accessing

Description

stTargets

SERT.ST_GeneratedTargetsData

Read/write

Targets to be displayed on the conveyor. Must be updated cyclically.

The targets set via the property stTargets are displayed on the conveyor in the conveyor view.

Ensure, that the targets match the current plane and offset of the conveyor such that they are displayed correctly.

xHomingSensor

BOOL

Read/write

Input for homing on sensor.

xHwLimitSwitchNeg

BOOL

Read/write

Value for AXM.ST_ModuleInterface.ST_Main.i_xHwLimitSwitchNeg.

xHwLimitSwitchPos

BOOL

Read/write

Value for AXM.ST_ModuleInterface.ST_Main.i_xHwLimitSwitchPos.

Methods

Name

Description

Logic

Logic for the conveyor.

RegisterLoggerPoint

Register the Smart Template Conveyor Module to the Application Logger.

GetDimensions

Read the length and width of the conveyor.