Data Exchange with ModuleInterface

Overview

If you want to exchange data with the conveyor, there are several ways to accomplish this.

Via ModuleInterface

The most efficient way is via ModuleInterface.

Step

Action

1

Open the ModuleInterface.

G-SE-0078269.1.gif-high.gif

 

1   STANDARD_INTERFACE

2   USER_INTERFACE

3   Textual view

4   Tabular view

The ModuleInterface provides two sections: STANDARD_INTERFACE (1) and USER_INTERFACE (2).

2

Add variables in the:

oTextual view (3) or

oTabular view (4)

3

If you add VAR_INPUT, VAR_OUTPUT or VAR_INPUT_OUTPUT you must update the call of the conveyor).

4

If you use the Code Generation Option for Non-Template Conveyors, the call of the conveyor is updated automatically.

Via Method

Step

Action

1

Right-click the Conveyor object to add, for example, a method.

2

You can use the method to set/get data of the conveyor.

Via Global Variables

Step

Action

1

Add a global variable to use it inside and outside of the conveyor.

2

As Data type you can use the standard data types (BOOL, LREAL, ...) or user-defined data types (for example ST_MyStruct).

Save Data

Variables, which have been defined in methods are volatile and are reinitialized with each call of the method.

If you need nonvolatile variables to save data, you must define the variables in the ModuleInterface.