What is EcoStruxure Machine Expert
EcoStruxure Machine Expert is a professional, efficient and open Original Equipment Manufacturers (OEM) software solution that aides you in the developing, configuring and commissioning of the entire machine in a single environment (including logic, motor control, and related network automation functions).
EcoStruxure Machine Expert allows you to program and commission the entire range of elements in the Schneider Electric Flexible Machine Control offer, and helps you to achieve the most optimized control solution for most machine requirements.
Schneider Electric Flexible Machine Control
Schneider Electric Flexible Machine Control is the comprehensive solution-oriented offer for OEMs that includes the following elements:
o1 software environment
oEcoStruxure Machine Expert
o2 hardware control platform types
ologic controller
omotion controller
oother devices
oHMI
ospeed drives, servo drives, motor drives
osensors
odistributed I/O modules, etc.
oindustrial PCs (iPCs)
EcoStruxure Machine Expert integrates:
oHMI controllers
oHarmony SCU HMI Controller
oLogic controllers
oModicon M241
oModicon M251
oModicon M258
oModicon M262
oMotion controllers
oModicon LMC058
oModicon M262
oPacDrive LMC Eco
oPacDrive LMC Pro/Pro2
oHMI Harmony graphic panels
oHarmony XBTGH
oHarmony GK
oHarmony GTO
oHarmony GTU
oHarmony GTUX
Other HMI graphic panels are supported via the Modbus connection which do not support the Machine Expert protocol.
EcoStruxure Machine Expert provides the following features and functions:
oentire range of IEC 61131-3 languages
ointegrated fieldbus configurators
ointegrated Axis editor
oexpert diagnostics and debugging
ovisualization screen
osecurity screen
oupgrading software and online help via the Machine Expert Installer
ointegrated function block finder to simplify programming
ointegrated Functional Tree to group and display the content of a controller according to your individual requirements
ointegrated OPC DA and OPC UA server
ooptional installation of the HMI application development tool Vijeo-Designer
ooptional installation of EcoStruxure Machine Expert - Safety to configure safety controller.
ooptional installation of the Controller Assistant to manage firmware and application download
oapplication and function templates
omachine code analysis
osmart template integrated in standard projects
ocreate and configure controller certificates
oenable project file encryption
odata exchange between service tools such as Motion Sizer and EcoStruxure Machine Expert
With EcoStruxure Machine Expert you can design a complete solution with just:
o1 software program
o1 project file
o1 cable connection
o1 download
EcoStruxure Machine Expert integrates tested, validated, documented and supported expert application libraries and project templates dedicated to many OEM applications. A simple configuration methodology speeds up design, commissioning, installation and troubleshooting.
For more information, refer to the Libraries Overview.