Permissions...

Overview

The Project > User Management > Permissions... command opens the Permissions dialog box for configuring the rights to work on objects to perform commands in the open project or to modify the user management configuration. The rights concerning objects can also be configured in the Properties dialog box of the object.

In a new project, only the username Owner (group Owner) has the permission to modify the users, groups, and permission configuration. You can log on to the project (Logon) with username Owner and empty password to assign this permission to another group.

NOTE: The changes made in this dialog box will be applied immediately.

G-SE-0030604.3.gif-high.gif

 

 

The Actions window displays the rights. These are the actions which can be performed on any object of the project. The tree is structured in the following way:

oG-SE-0028084.1.gif-high.gif Top-level see the names of some categories, which have been set up just for optical structuring the right management. The rights are grouped regarding the following actions: Execution of Commands, the creation of Object Types, the viewing, editing, removing, and handling of child objects of Project Objects and the configuration of User accounts, groups, and permissions.

oBelow each category node there are nodes for the particular actions (yellow flash icon) which can be performed on the command, user account, group, object type, or project object. These nodes only have optical function, too.

Possible actions:

execute

Execution of a menu command.

create

Creating a new object in the project.

add or remove children

Adding or removing child objects to an existing object.

modify

Editing an object in an editor or editing the users, groups, and permission configuration.

remove

Deleting or cutting an object.

NOTE: To grant the right for removing an object, make sure that the add or remove children right is granted to the parent of this object.

view

Viewing an object in an editor.

oBelow each action node, find the possible targets (gray arrow icon) of the respective action. These can be project objects or the users, groups, and permission configuration.

The Permissions window provides a list of the available user groups (except the Owner group) and a toolbar for configuring rights to a group.

Select the group and configure its permissions.

To the left of each group name one of the following icons indicates the assigned permission concerning the target which is selected in the Actions window:

+ (green)

The actions for the targets selected in the Actions window are granted for the selected group.

- (red)

The actions for the targets selected in the Actions window are denied for the selected group.

+ (gray)

The right to perform the actions which are selected for the selected targets in the Actions window has not been granted explicitly, but is granted by default, for example because the corresponding right has been granted to the father object. Example: The group has received the right for object myplc, thus by default it also has got it for object myplc.pb_1. Basically, granted is the default setting for all rights which have not been explicitly configured differently. Note, however, the exception: The right to modify the users, groups, and permission configurations initially is only granted to the username Owner. Also refer to User Management.

- (gray)

The right to perform the actions which are selected for the selected targets in the Actions window, has not been denied explicitly, but is denied by default, for example in case because the corresponding right has been assigned to the father object.

If multiple actions are selected in the Actions window, which does not have unique settings referring to the selected group, no icon is displayed.

To configure the rights for a group, select the desired actions and targets in the Actions window and the desired group in the Permissions window. Then click the appropriate button in the toolbar of the Permissions window:

Grant (green +)

explicit granting

Deny (red -)

explicit denying

Clear (gray X)

The granted right for the actions selected in the Actions window will be deleted. It is set back to the default.