Executing Scripts

Overview

You can execute script files (filename.py), containing a sequence of script commands, from the EcoStruxure Machine Expert user interface.

For further information on running scripts form the EcoStruxure Machine Expert user interface, refer to the chapter Script-Related Commands.

Batch Files

Frequently used commands

Command

Description

-    REM  or ::

The line is a comment and will be ignored.

cd

Changes to another directory.

echo off

The commands will not be displayed.

In order to prevent single commands from being displayed, insert an @ character in front of the command.

echo

Displays a string or a variable on the programming console.

set

Declares a variable and assigns a value to this variable.

>

Writes the output to a file. If the file already exists, it will be overwritten.

>>

Appends the output to a file. If the file does not already exist, it will be created.

Application example:

@echo off
REM Go to the directory where EcoStruxure Machine Expert is installed
cd "<Replace this with the path to the LogicBuilder.exe, for example, C:\Program Files (x86)\Schneider Electric\SoMachine Software\>"
REM Run LogicBuilder.exe with no graphical user interface and the full path to the script
LogicBuilder.exe --noui --runscript="<Replace this with the full file path where the script is stored, for example, D:\MyScripts\TestScript.py>"
pause

C# Console Application

Running the script in a C# application allows you to edit the script dynamically before the script is executed by the engine. In addition, some previous steps can be performed in the C# application as well

using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Diagnostics;
namespace ExecuteScriptExample
{
    class Program
    {
        static void Main(string[] args)
        {
            try
            {
                ProcessStartInfo psi = new ProcessStartInfo();
                
                // Specify the name and the arguments you want to pass
                psi.FileName = @"<Replace this with the path to the LogicBuilderShell.exe, for example, C:\Program Files (x86)\Schneider Electric\SoMachine Software\LogicBuilderShell.exe";
                psi.Arguments = "\ "<Replace this with the full file path where the script is stored, for example, D:\MyScripts\TestScript.py\"";
                // Create new process and set the starting information
                Process p = new Process();
                p.StartInfo = psi;
                // Set this so that you can tell when the process has completed
                p.EnableRaisingEvents = true;
                p.Start();
                // Wait until the process has completed
                while (!p.HasExited)
                {
                    System.Threading.Thread.Sleep(1000);
                }
            }
            catch (Exception ex)
            {
                Console.Write(ex.Message);
            }
            Console.ReadKey();
        }
    }
}