You define tappet paths in this table graphical editor. A tappet path defines one or more tappets depending on the master position. At the upper edge of the editor window, a horizontal axis approaches the range of the master positions. The individual tappet paths follow below.
You can switch between the graphical editor and the table editor at any time.
|
Track ID of the tappet path All tappets of a tappet path refer to the same tappet switch (a variable of type BOOL). |
|
Select the tappets by means of this tool. You can drag selected tappets to another position.
You can modify the switch on/off attribute of a tappet by clicking the relevant end of the crossed line ( Delete the selected tappet by pressing the Del key. |
|
Add new tappets with this tool. Click the insertion point in the path. |
The tappet is assigned to a result, if it is passed from the position of the master axis in the positive (increasing master values) or negative direction. |
|
X |
Position of the tappet |
Positive pass |
Switch on/off attribute
|
Negative pass |
Switch on/off attribute
|
Table of the possible combinations of tappet attributes
Tappet symbol |
Positive pass |
Negative pass |
|
No action |
No action |
|
Switch to ON |
No action |
|
Switch to OFF |
No action |
|
No action |
Switch to ON |
|
No action |
Switch to OFF |
|
Switch to ON |
Switch to OFF |
|
Switch to ON |
Switch to OFF |
|
Switch to OFF |
Switch to ON |
|
Switch to OFF |
Switch to OFF |
|
Invert |
No action |
|
No action |
Invert |
|
Switch to ON |
Invert |
|
Invert |
Switch to ON |
|
Invert |
Switch to OFF |
|
Switch to OFF |
Invert |
|
Invert |
Invert |