Directory (EXAMPLE)

 

(* example of how to use the CAA_FILE library - directory function blocks *)

PROGRAM DIR_PRG

VAR
  xDirInit:       BOOL := FALSE;
  uiDirState:     UINT := 0;
  sDirNewName:    STRING:='./TestDirectory';
  sDirNextName:   STRING:='./NewDirectory';
  hDir:           CAA.HANDLE;
  deNewDirectory: FILE.FILE_DIR_ENTRY;
  fildcr:         FILE.DirCreate;
  fildop:         FILE.DirOpen;
   fildcl:         FILE.DirClose;
   fildls:         FILE.DirList;
   fildrn:         FILE.DirRename;
   fildrm:         FILE.DirRemove;
END_VAR

IF NOT xDirInit THEN
  fildcr(xExecute:=FALSE);
  fildcl(xExecute:=FALSE);
  fildls(xExecute:=FALSE);
  fildrm(xExecute:=FALSE);
  xDirInit:=TRUE;
  uiDirState:=0;

  CASE uiDirState OF
  0: (* create a new directory *)
  fildcr.sDirName:=sDirNewName;
  fildcr.xParent:=FALSE;
  fildcr( xExecute:=TRUE);
    IF fildcr.xDone THEN
       uiDirState:=1;
    END_IF
    IF fildcr.xError THEN
    (* error handling*)
       ;
    END_IF
  1:(* open directory *)
  fildop.sDirName:=sDirNewName;
  fildop( xExecute:=TRUE);
    IF fildop.xDone THEN
       hDir := fildop.hDir;
       uiDirState:=2;
    END_IF
    IF fildop.xError THEN
    (* error handling*)
       ;
    END_IF
  2:(* get directory property list *)
    fildls.hDir:=hDir;
    fildls( xExecute:=TRUE);
    IF fildls.xDone THEN
       deNewDirectory.sEntry :=fildls.deDirEntry.sEntry;
       deNewDirectory.szSize :=fildls.deDirEntry.szSize;
       deNewDirectory.xDirectory :=fildls.deDirEntry.xDirectory;
       deNewDirectory.xExclusive :=fildls.deDirEntry.xExclusive;
        deNewDirectory.dtLastModification :=fildls.deDirEntry.dtLastModification;
       uiDirState:=3;
    END_IF
    IF fildop.xError THEN
    (* error handling*)
       ;
    END_IF
  3:(* close directory *)
    fildcl.hDir:=hDir;
    fildcl( xExecute:=TRUE);
    IF fildcl.xDone THEN
       uiDirState:=4;
    END_IF
    IF fildcl.xError THEN
    (* error handling*)
       ;
    END_IF
  4:(* rename directory*)
    fildrn.sDirNameOld:=sDirNewName;
    fildrn.sDirNameNew:=sDirNextName;
    fildrn( xExecute:=TRUE);
    IF fildrn.xDone THEN
       uiDirState:=5;
    END_IF
    IF fildrn.xError THEN
    (* error handling*)
       ;
    END_IF
  5:(* remove directory*)
    fildrm.sDirName:=sDirNextName;
    fildrm.udiTimeOut:=100000;    (* 100ms TimeOut *)
    fildrm.xRecursive:=FALSE;
    fildrm( xExecute:=TRUE);
    IF fildrm.xDone THEN
       uiDirState:=6;
    END_IF
    IF fildrm.xError THEN
    (* error handling*)
       ;
    END_IF
  6: (* end of example*)
       ;
    END_CASE
END_IF