Environmental Specifications

 

Physical environment

Surrounding air temperature

0...55 °C (32...131 °F)

Storage temperature

-20...60 °C (-4...140 °F)

Surrounding air and storage humidity

10...90% RH (Non condensing, wet bulb temperature 39 °C [102.2 °F] or less)

Dust

0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)

Pollution degree

For use in Pollution Degree 2 environment

Corrosive gases

Free of corrosive gases

Atmospheric pressure (operating altitude)

800...1,114 hPa (2,000 m [6,561 ft] or lower)

Mechanical environment

Vibration resistance

IEC/EN 61131-2 compliant

5...9 Hz Single amplitude 3.5 mm (0.14 in)

9...150 Hz Fixed acceleration: 9.8 m/s2

X, Y, Z directions for 10 cycles (approximately 100 minutes)

Shock resistance

IEC/EN 61131-2 compliant

147 m/s2, X, Y, Z directions for 3 times

Electrical environment

Noise immunity

Noise voltage: 1,000 Vp-p

Pulse duration: 1 μs

Rise time: 1 ns

(via noise simulator)

Electrostatic discharge immunity

Contact discharge method: 6 kV

Air discharge method: 8 kV

(IEC/EN 61000-4-2 Level 3)

NOTE: When using any of the options for this product, make sure to check the specifications for any special conditions or cautions that may apply to this product.

Air quality requirements

Do not operate or store the panel where chemicals evaporate, or where chemicals are present in the air:

oCorrosive chemicals: Acids, alkalines, liquids containing salt.

oFlammable chemicals: Organic solvents.

Caution_Color.gifCAUTION

INOPERATIVE EQUIPMENT

Do not allow water, liquids, metal, and wiring fragments to enter the panel case.

Failure to follow these instructions can result in injury or equipment damage.