EXPERTGetCapturedValue: Returns Content of Capture Registers
This administrative function block returns the content of a capture register.
To see the general representation in IL or ST language, refer to Function and Function Block Representation.
This table describes the input variables:
|
Inputs |
Type |
Comment |
|---|---|---|
|
EXPERT_REF_IN |
Reference to the EXPERT function block. Must not be changed during block execution. |
|
|
Execute |
BOOL |
On rising edge, starts the function block execution. On falling edge, resets the outputs of the function block when its execution terminates. |
|
CaptureNumber |
BYTE |
Index of the capture register: ofor HSCMain: always 0 ofor Encoder: 0: Cap0, 1: Cap1, or 2: Distance |
This table describes the output variables:
|
Outputs |
Type |
Comment |
|---|---|---|
|
EXPERT_REF_OUT |
Reference to the EXPERT function block. |
|
|
Done |
BOOL |
TRUE = indicates that CaptureValue is valid. Function block execution is finished. |
|
Busy |
BOOL |
TRUE = indicates that the function block execution is in progress. |
|
Error |
BOOL |
TRUE = indicates that an error was detected. Function block execution is finished. |
|
ErrID |
When Error is TRUE: type of the detected error. |
|
|
CaptureValue |
DINT |
When Done is TRUE: Capture register value is valid. |
NOTE: In case of detected error, variables take the last value captured.
NOTE: For more information about Done, Busy and Execution pins, refer to General Information on Function Block Management.
Adding the EXPERTGetCapturedValue Function Block
|
Step |
Description |
|---|---|
|
1 |
Select the Libraries tab in the Software Catalog and click Libraries. Select Controller > LMC058 > LMC058 Expert IO > Administrative > EXPERTGetCapturedValue in the list, drag-and-drop the item onto the POU window. |
|
2 |
Link the EXPERT_REF_IN input to the HSC_REF output of the HSC. |