About the Book
This manual describes the hardware implementation of the Modicon TM5 field bus interface. It provides parts descriptions, specifications, wiring diagrams, installation and setup for Modicon TM5 field bus interface.
This document has been updated for the release of EcoStruxureTM Machine Expert V1.2.5.
The technical characteristics of the devices described in the present document also appear online. To access the information online:
Step |
Action |
---|---|
1 |
Go to the Schneider Electric home page www.schneider-electric.com. |
2 |
In the Search box type the reference of a product or the name of a product range. oDo not include blank spaces in the reference or product range. oTo get information on grouping similar modules, use asterisks (*). |
3 |
If you entered a reference, go to the Product Datasheets search results and click on the reference that interests you. If you entered the name of a product range, go to the Product Ranges search results and click on the product range that interests you. |
4 |
If more than one reference appears in the Products search results, click on the reference that interests you. |
5 |
Depending on the size of your screen, you may need to scroll down to see the datasheet. |
6 |
To save or print a datasheet as a .pdf file, click Download XXX product datasheet. |
The characteristics that are described in the present document should be the same as those characteristics that appear online. In line with our policy of constant improvement, we may revise content over time to improve clarity and accuracy. If you see a difference between the document and online information, use the online information as your reference.
Title of Documentation |
Reference Number |
---|---|
PacDrive TM5 / TM7 Flexible System- System Planning and Installation Guide |
|
PacDrive TM5 / TM7 Safety Flexible System - System Planning and Installation Guide |
You can download these technical publications and other technical information from our website at https://www.se.com/ww/en/download/ .
|
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH |
oDisconnect all power from all equipment including connected devices prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires except under the specific conditions specified in the appropriate hardware guide for this equipment. oAlways use a properly rated voltage sensing device to confirm the power is off where and when indicated. oReplace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit. oUse only the specified voltage when operating this equipment and any associated products. |
Failure to follow these instructions will result in death or serious injury. |
|
POTENTIAL FOR EXPLOSION |
oOnly use this equipment in non-hazardous locations, or in locations that comply with Class I, Division 2, Groups A, B, C and D. oDo not substitute components which would impair compliance to Class I, Division 2. oDo not connect or disconnect equipment unless power has been removed or the location is known to be non-hazardous. oDo not use the USB port(s), if so equipped, unless the location is known to be non-hazardous. |
Failure to follow these instructions will result in death or serious injury. |
|
LOSS OF CONTROL |
oThe designer of any control scheme must consider the potential failure modes of control paths and, for certain critical control functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are emergency stop and overtravel stop, power outage and restart. oSeparate or redundant control paths must be provided for critical control functions. oSystem control paths may include communication links. Consideration must be given to the implications of unanticipated transmission delays or failures of the link. oObserve all accident prevention regulations and local safety guidelines.1 oEach implementation of this equipment must be individually and thoroughly tested for proper operation before being placed into service. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
1 For additional information, refer to NEMA ICS 1.1 (latest edition), "Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control" and to NEMA ICS 7.1 (latest edition), "Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable-Speed Drive Systems" or their equivalent governing your particular location.
|
UNINTENDED EQUIPMENT OPERATION |
oOnly use software approved by Schneider Electric for use with this equipment. oUpdate your application program every time you change the physical hardware configuration. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |