Mit der Erweiterung „Applikation bereinigen und erstellen“ können Sie ein Projekt bereinigen oder ein neues Projekt erstellen.
# Enable the new python 3 print syntax
from __future__ import print_function
# The path to the project
project_path = r"D:\PythonProjects\Example.project"
# Clean up any open project:
if projects.primary:
projects.primary.close()
# Load the project
proj = projects.open(project_path);
# Fetch the active application.
app = proj.active_application
# Clean application
app.clean()
# Compile application and store compiler messages in a list
app.build()
for msg_cat in system.get_message_categories():
if system.get_message_category_description(msg_cat) == "Build":
messages = system.get_message_objects(msg_cat, Severity.Warning | Severity.Error | Severity.FatalError)
break
# If length of messages list is 0, the build was successful
print("--- Build successful ---")
# Otherwise print results
else:
for msg in messages:
if hasattr(msg, 'object'):
texts = [str(msg.severity), msg.text, msg.object.get_name()]
else:
texts = [str(msg.severity), msg.text]
print("; ".join(texts))