About the Book
This manual describes the configuration and usage of the Magelis Box iPC and displays, part of the range of Magelis Industrial PC, for its cataloged and configured product offers.
The Magelis Box iPC are designed to operate in an industrial environment.
1 Cataloged product offer:
oHMIBMIEA5DD1101 - Box iPC Basic Optimized - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o64 GB eMMc (soldered)
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot
o1 mini PCIe for optional interface
oHMIBMIEA5DD110L - Box iPC Basic Optimized - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o128 GB eMMc (soldered)
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot
o1 mini PCIe for optional interface
oHMIBMIEA5DD1E01 - IIoT Smart Box - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o64 GB eMMc (soldered)
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot, TPM 2.0 module
o1 mini PCIe for optional interface
oHMIBMIEA5DD1001 - Box iPC Basic Optimized - DC - Base unit - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o64 GB eMMc (soldered)
o1 mini PCIe for optional interface
oHMIBMIEA5DD100A - Box iPC Basic Optimized - DC - Base unit - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o128 GB eMMc (soldered)
o1 mini PCIe for optional interface
oConformal coating
oHMIBMOMA5DD1E01 - IIoT Edge Box Regular - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o64 GB M.2 SSD
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot, TPM 2.0 module
o1 mini PCIe
oHMIBMOMA5DD1101 - Box iPC Optimized Regular - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o64 GB M.2 SSD
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot
o1 mini PCIe
oHMIBMO0A5DD1001 - Box iPC Optimized Regular - DC - Base unit - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o1 mini PCIe
oHMIBMOMA5DDF10L - Box iPC Optimized Expandable - DC - Win 10 - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o256 GB M.2 SSD
o2.5" HDD/SSD slot
oWindows 10 IoT Enterprise 2016 LTSB Entry, UEFI boot
o1 mini PCIe for optional interface
oHMIBMO0A5DDF101 - Box iPC Optimized Expandable - DC - Base unit - 1 slot
o12...24 Vdc
oAtom E3930 processor
o4 GB RAM
o2.5" HDD/SSD slot
o1 mini PCIe for optional interface
oHMIBMO0A5DDF10A - Box iPC Optimized Expandable - DC - Base unit - 1 slot
o12...24 Vdc
oAtom E3930 processor
o8 GB RAM
o2.5" HDD/SSD slot
o1 mini PCIe for optional interface
oConformal coating
oHMIBMUHI29D2801 - Box iPC Universal HDD - DC - Win 8.1 - 2 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o500 GB Hard disk drive (HDD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe
oHMIBMUSI29D2801 - Box iPC Universal SSD - DC - Win 8.1 - 2 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o150 GB Flash drive (SSD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe
oHMIBMUCI29D2W01 - Box iPC Universal CFast - DC - WES - 2 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o32 GB CFast card
oWindows Embedded Standard 7 (WES7P) SP1 64 bit MUI
o2 mini PCIe
oHMIBMU0I29D2001 - Box iPC Universal - DC - Base unit - 4 GB - 2 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o2 mini PCIe
oHMIBMU0I29D200A - Box iPC Universal - DC - Base unit - 8 GB - 2 slots
o24 Vdc
oCeleron-2980U processor
o8 GB RAM
o2 mini PCIe
oConformal coating
oHMIBMUHI29D4801 - Box iPC Universal HDD - DC - Win 8.1 - 4 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o500 GB Hard disk drive (HDD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMUSI29D4801 - Box iPC Universal SSD - DC - Win 8.1 - 4 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o150 GB Flash drive (SSD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMUCI29D4W01 - Box iPC Universal CFast - DC - WES - 4 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o32 GB CFast card
oWindows Embedded Standard 7 (WES7P) SP1 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMU0I29D4001 - Box iPC Universal - DC - Base unit - 4 slots
o24 Vdc
oCeleron-2980U processor
o4 GB RAM
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMU0I29D400A - Box iPC Universal - DC - Base unit - 4 slots
o24 Vdc
oCeleron-2980U processor
o8 GB RAM
o2 mini PCIe + 1 PCI + 1 PCIe
oConformal coating
oHMIBMU0I29DI00A - Box iPC Universal - DC - Base unit - 4 slots
o24 Vdc
oCeleron-2980U processor
o8 GB RAM
o2 mini PCIe + 2 PCI
oConformal coating
oHMIBMU0I29DE00A - Box iPC Universal - DC - Base unit - 4 slots
o24 Vdc
oCeleron-2980U processor
o8 GB RAM
o2 mini PCIe + 2 PCIe
oConformal coating
oHMIBMPHI74D2801 - Box iPC Performance HDD - DC - Win 8.1 - 2 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o500 GB Hard disk drive (HDD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe
oHMIBMPSI74D2801 - Box iPC Performance SSD - DC - Win 8.1 - 2 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o150 GB Flash drive (SSD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe
oHMIBMP0I74D2001 - Box iPC Performance - DC - Base unit - 2 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o2 mini PCIe
oHMIBMP0I74D200A - Box iPC Performance - DC - Base unit - 2 slots
o24 Vdc
oi7-4650U processor
o16 GB RAM
o2 mini PCIe
oConformal coating
oHMIBMPHI74D4801 - Box iPC Performance HDD - DC - Win 8.1- 4 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o500 GB Hard disk drive (HDD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMPSI74D4801 - Box iPC Performance SSD - DC - Win 8.1 - 4 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o150 GB Flash drive (SSD)
oWin 10 IoT Enterprise 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMPSI74D470L - Box iPC Performance SSD - DC - Win 7 - 4 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o160 GB Flash drive (SSD)
oWindows 7 Ultimate SP1 64 bit MUI
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMP0I74D4001 - Box iPC Performance - DC - Base unit - 4 slots
o24 Vdc
oi7-4650U processor
o8 GB RAM
o2 mini PCIe + 1 PCI + 1 PCIe
oHMIBMP0I74D400A - Box iPC Performance - DC - Base unit - 4 slots
o24 Vdc
oi7-4650U processor
o16 GB RAM
o2 mini PCIe + 1 PCI + 1 PCIe
oConformal coating
oHMIBMP0I74DI00A - Box iPC Performance - DC - Base unit - 4 slots
o24 Vdc
oi7-4650U processor
o16 GB RAM
o2 mini PCIe + 2 PCI
oConformal coating
oHMIBMP0I74DE00A - Box iPC Performance - DC - Base unit - 4 slots
o24 Vdc
oi7-4650U processor
o16 GB RAM
o2 mini PCIe + 2 PCIe
oConformal coating
oHMIDM6421 - display 4:3 12” single touch for Box iPC.
oHMIDM6521 - display W12” multi-touch for Box iPC.
oHMIDM7421 - display 4:3 15” single touch for Box iPC.
oHMIDM7521 - display W15” multi-touch for Box iPC.
oHMIDM9521 - display W19” multi-touch for Box iPC.
oHMIDMA521 - display W22” multi-touch for Box iPC.
oHMIDADP11 - Display Adapter for display module.
NOTE: The part number for your unit may not be included in the user manual. Commercial part numbers listed in the user manual are for products available when the user manual was published. New part numbers may be added to the product range.
New and existing cataloged part numbers are always composed of a prefix (HMI), followed by a serial arrangement of 12 alphanumeric characters. Each one of the twelve characters matches with one characteristic of the cataloged Magelis Box iPC Optimized, Universal or Performance, such as storage device size, storage device type, memory size, and bundled software.
Use the following legend to identify the features that correspond with each character of the part number:
Character number |
Prefix |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Part number |
HMI |
|
||||||||||||
Range name |
Magelis Box iPC Optimized, Universal or Performance |
|
|
|
||||||||||
iPC family |
|
B |
||||||||||||
Type |
|
M |
||||||||||||
Version |
Fully Optimized |
I |
|
|||||||||||
Optimized |
O |
|||||||||||||
Universal |
U |
|||||||||||||
Performance |
P |
|||||||||||||
Drive |
Hard disk drive (HDD) |
H |
|
|||||||||||
Flash drive (SSD) |
S |
|||||||||||||
CFast card (CF) |
C |
|||||||||||||
M.2 SSD |
M |
|||||||||||||
eMMc (soldered) |
E |
|||||||||||||
None |
0 |
|||||||||||||
CPU type |
Atom E3930 |
A |
5 |
D |
|
|||||||||
Core i7-4650U |
I |
7 |
4 |
|||||||||||
Celeron 2980U |
I |
2 |
9 |
|||||||||||
Power supply |
DC |
D |
|
|||||||||||
Expansion slots |
1 mini PCIe |
1 |
|
|||||||||||
2 mini PCIe |
2 |
|||||||||||||
2 mini PCIe and PCIe and PCI |
4 |
|||||||||||||
2 mini PCIe and 2 PCI |
I |
|||||||||||||
2 mini PCIe and 2 PCIe |
E |
|||||||||||||
1 mini PCIe for optional interface + 2.5" HDD/SSD slot |
F |
|||||||||||||
Operating system |
None |
0 |
|
|||||||||||
Windows Embedded Standard 7 (WES7P) SP1 64 bit MUI |
W |
|||||||||||||
Windows 7 Ultimate SP1 64 bit MUI |
7 |
|||||||||||||
Windows Embebded 8.1 Industry 64 bit MUI |
8 |
|||||||||||||
Windows 10 IoT Enterprise 2016 LTSB entry |
1 |
|||||||||||||
Windows 10 IoT Enterprise 2016 LTSB entry, UEFI boot, TPM 2.0 module, Node-RED |
E |
|||||||||||||
Bundled software |
None |
0 |
|
|||||||||||
Hardware iteration |
Initial |
1 |
||||||||||||
Conformal coating |
A |
|||||||||||||
To be completed |
L |
2 Configured product offer:
In addition to the catalog offer, other configurations may be available in some countries.
These configured offers use a fixed method of identification. The configured part numbers are always composed of an arrangement of 20 alphanumeric characters. The first 6 characters are always HMIPCC. The remaining 14 characters match with one characteristic of the configured Magelis Box iPC Optimized, Universal or Performance, such as storage device size, storage device type, memory size, and bundled software.
The configured offers have similar characteristics and functionalities as the cataloged offer described in this manual.
In addition to this part number, a configuration number is printed on the product label.
The configuration number format is as follows:
Character number |
Prefix (1-6) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Part number |
HMI PCC |
|
|||||||||||||
Form factor |
Modular Atom PC |
L |
|
||||||||||||
Modular Celeron PC |
U |
||||||||||||||
Modular Core i7 PC |
P |
||||||||||||||
Display Adapter |
A |
||||||||||||||
Product generation |
Second generation |
2 |
|
||||||||||||
Modular displays |
None |
B |
|
||||||||||||
Display PC 4:3 12" - XGA |
6 |
||||||||||||||
Display PC W12" - WXGA |
D |
||||||||||||||
Display PC 4:3 15" - XGA |
7 |
||||||||||||||
Display PC W15" - FWXGA |
J |
||||||||||||||
Display PC W19" - FWXGA |
L |
||||||||||||||
Display PC W21" - FHD |
N |
||||||||||||||
Box iPC modular |
None |
N |
|
||||||||||||
Box iPC modular Universal DC 4 GB RAM |
C |
||||||||||||||
Box iPC modular Universal DC 8 GB RAM |
D |
||||||||||||||
Box iPC modular Universal DC 4 GB RAM, 1 PCI, and 1 PCIe |
E |
||||||||||||||
Box iPC modular Universal DC 8 GB RAM, 1 PCI, and 1 PCIe, conformal coating |
F |
||||||||||||||
Box iPC modular Universal DC 8 GB RAM, 2 PCI, conformal coating |
G |
||||||||||||||
Box iPC modular Universal DC 8 GB RAM, 2 PCIe, conformal coating |
H |
||||||||||||||
Box iPC modular Performance DC 8 GB RAM |
J |
||||||||||||||
Box iPC modular Performance DC 16 GB RAM |
U |
||||||||||||||
Box iPC modular Performance DC 8 GB RAM, 1 PCI and1 PCIe |
K |
||||||||||||||
Box iPC modular Performance DC 16 GB RAM, 1 PCI, and 1 PCIe, conformal coating |
L |
||||||||||||||
Box iPC modular Performance DC 16 GB RAM, 2 PCI, conformal coating |
M |
||||||||||||||
Box iPC modular Performance DC 16 GB RAM, 2 PCIe, conformal coating |
O |
||||||||||||||
Box iPC modular Optimized DC 4 GB RAM |
1 |
||||||||||||||
Box iPC modular Optimized DC 4 GB RAM, expandable |
2 |
||||||||||||||
Box iPC modular Optimized DC 8 GB RAM, expandable, conformal coating |
4 |
|
|
|
|
|
|
|
|
|
|
||||
Box iPC modular Basic Optimized DC 4 GB RAM, eMMc (soldered) 64 GB |
5 |
|
|
|
|
|
|
|
|
|
|
||||
Box iPC modular Basic Optimized DC 4 GB RAM, eMMc (soldered) 128 GB |
6 |
|
|
|
|
|
|
|
|
|
|
||||
CPU type |
None (Display Adapter) |
N |
|
||||||||||||
Box iPC Optimized - Atom-E3930 fanless |
B |
||||||||||||||
Box iPC Universal - Celereon 2980U fanless |
C |
||||||||||||||
Box iPC Universal - Celeron 2980U with fan kit for expansion card above 3 W |
F |
||||||||||||||
Box iPC Performance - Core i7-4650U fanless |
7 |
||||||||||||||
Box iPC Performance - Core i7-4650U with fan kit for expansion card above 3 W |
W |
||||||||||||||
Power supply |
AC (including for Hazardous Locations) |
A |
|
||||||||||||
AC (not for Hazardous Locations) |
B |
||||||||||||||
DC |
D |
||||||||||||||
RAM |
None (Display Adapter) |
N |
|
||||||||||||
1 GB |
1 |
||||||||||||||
2 GB |
2 |
||||||||||||||
4 GB |
4 |
||||||||||||||
8 GB |
8 |
||||||||||||||
16 GB |
A |
||||||||||||||
Operating system |
None |
0 |
|
||||||||||||
Windows Embedded Standard 7 (WES7P) SP1 64 bit MUI |
4 |
||||||||||||||
Windows 7 Ultimate SP1 64 bit MUI |
6 |
||||||||||||||
Windows Embebded 8.1 Industry 64 bit MUI |
8 |
||||||||||||||
Windows 10 IoT Enterprise 64 bit MUI for Box iPC Optimized |
A |
||||||||||||||
Windows 10 IoT Enterprise 64 bit MUI for Box iPC Universal |
B |
||||||||||||||
Windows 10 IoT Enterprise 64 bit MUI for Box iPC Performance |
C |
||||||||||||||
Storage device |
None |
N |
|
||||||||||||
CFast 32 GB |
X |
||||||||||||||
HDD 500 GB for Box iPC Universal and Performance |
J |
||||||||||||||
HDD 1 TB for Box iPC Universal and Performance |
K |
||||||||||||||
SSD 128 GB for Box iPC Universal and Performance |
L |
||||||||||||||
SSD 256 GB for Box iPC Universal and Performance |
P |
||||||||||||||
M.2 65 GB for Box iPC Optimized |
1 |
||||||||||||||
M.2 128 GB for Box iPC Optimized |
2 |
||||||||||||||
M.2 256 GB for Box iPC Optimized |
3 |
||||||||||||||
eMMc (soldered) for Box iPC HMIBMI |
4 |
||||||||||||||
Optional interfaces |
None |
0 |
|
||||||||||||
Interface - NVRAM |
1 |
||||||||||||||
Interface - 2 x RS 422/485 isolated |
2 |
||||||||||||||
Interface - 4 x RS 422/485 |
3 |
||||||||||||||
Interface - 2 x USB 3.0 |
4 |
||||||||||||||
Interface - 2 x RS 232 isolated |
5 |
||||||||||||||
Interface - 4 x RS 232C |
6 |
||||||||||||||
Interface - 16 x DI / 8 x DO |
8 |
||||||||||||||
Interface - audio (pin header) for Box iPC Universal and Performance |
C |
||||||||||||||
Interface - audio |
A |
||||||||||||||
Interface - Cellular 3G |
D |
||||||||||||||
Interface - wireless LAN board and 2 x antennas |
E |
||||||||||||||
Interface - 2 x CANopen CANBus |
G |
||||||||||||||
Interface - 1 x PROFIBUS DP master NVRAM |
J |
||||||||||||||
TPM 2.0 module |
L |
||||||||||||||
Interface - transmistter to Display Adapter |
T |
||||||||||||||
Interface - Cellular 4G for US |
M |
||||||||||||||
Interface - Cellular 4G for EU /ASIA |
N |
||||||||||||||
Interface - DVI-I |
U |
||||||||||||||
Interface - DVI-D / 2 x VGA |
V |
||||||||||||||
Interface - DVI-D |
W |
||||||||||||||
Interface - 2 x VGA |
X |
||||||||||||||
Interface - mini PCIe 8 x analog input |
Z |
||||||||||||||
Second storage |
None |
N |
|
||||||||||||
CFast 32 GB in CFast slot |
X |
||||||||||||||
HDD 500 GB for Box iPC Universal and Performance |
J |
||||||||||||||
HDD 1 TB for Box iPC Universal and Performance |
K |
||||||||||||||
SSD 128 GB for Box iPC Universal and Performance |
L |
||||||||||||||
SSD 256 GB for Box iPC Universal and Performance |
P |
||||||||||||||
HDD 500 GB for Box iPC Optimized |
B |
||||||||||||||
HDD 1 TB for Box iPC Optimized |
D |
||||||||||||||
SSD 128 GB for Box iPC Optimized |
W |
||||||||||||||
SSD 256 GB for Box iPC Optimized |
Z |
||||||||||||||
Software bundle |
None |
N |
|
||||||||||||
Vijeo XD RT unlimited license |
X |
||||||||||||||
SoMachine Controller |
C |
||||||||||||||
Vijeo XL runtime 1.5 K license key code |
P |
||||||||||||||
Vijeo XL runtime 4 K license key code |
M |
||||||||||||||
Vijeo XL runtime 32 K license key code |
K |
||||||||||||||
Vijeo XL runtime 64 K license key code |
L |
||||||||||||||
Reserved |
None |
0 |
|
||||||||||||
Reserved |
None |
0 |
NOTE: All instructions applicable to the enclosed product and all safety precautions must be observed.
This document has been updated with the release of SoMachine V4.3.
The technical characteristics of the devices described in the present document also appear online. To access the information online:
Step |
Action |
---|---|
1 |
Go to the Schneider Electric home page www.schneider-electric.com. |
2 |
In the Search box type the reference of a product or the name of a product range. oDo not include blank spaces in the reference or product range. oTo get information on grouping similar modules, use asterisks (*). |
3 |
If you entered a reference, go to the Product Datasheets search results and click on the reference that interests you. If you entered the name of a product range, go to the Product Ranges search results and click on the product range that interests you. |
4 |
If more than one reference appears in the Products search results, click on the reference that interests you. |
5 |
Depending on the size of your screen, you may need to scroll down to see the data sheet. |
6 |
To save or print a data sheet as a .pdf file, click Download XXX product datasheet. |
The characteristics that are presented in the present document should be the same as those characteristics that appear online. In line with our policy of constant improvement, we may revise content over time to improve clarity and accuracy. If you see a difference between the document and online information, use the online information as your reference.
Registered trademarks
PL7, Vijeo, SoMachine, and Unity are registered trademarks of Schneider Electric.
Microsoft® and Windows® are registered trademarks of Microsoft corporation.
Intel®, Core i7® and Atom® are registered trademarks of Intel corporation.
The Box iPC HMIBMI, HMIPCC•2L, HMIPCC•2N, HMIPCCL2B5, HMIPCCL2B6, and the displays HMIDM9521, HMIDMA521 are not certified for use in Class I Division 2 hazardous (classified) locations.
|
POTENTIAL FOR EXPLOSION IN HAZARDOUS LOCATION |
Do not use these products in hazardous locations. |
Failure to follow these instructions will result in death or serious injury. |
The HMIBMP, HMIBMU, HMIBMO, HMIPCCP2B, HMIPCCU2B, HMIPCCL2B1...4, HMIPCCL2D1...4, HMIPCCL2J1...4, HMIPCCL261...4, HMIPCCL271...4, HMIPCCU26, HMIPCCU27, HMIPCCU2D, HMIPCCU2J, HMIPCCP26, HMIPCCP27, HMIPCCP2D, HMIPCCP2J, and the Display Adapter HMIDADP11 are certified for use in Class I Division 2 hazardous (classified) location (see chapter "Certifications and Standards"). Observe the following:
|
EXPLOSION HAZARD |
oAlways confirm the ANSI/ISA 12.12.01 and CSA C22.2 N°213 hazardous location rating of your device before installing or using it in a hazardous location. oTo power on or power off a Magelis Industrial PC installed in a Class I, Division 2 hazardous location, you must either: oUse a switch located outside the hazardous environment, or oUse a switch certified for Class I, Division 1 operation inside the hazardous area. oSubstitution of any components may impair suitability for Class I, Division 2. oDo not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. This applies to all connections including power, ground, serial, parallel, network, and rear USB connections. oNever use unshielded / ungrounded cables in hazardous locations. oWhen enclosed, keep enclosure doors and openings closed at all times to avoid the accumulation of foreign matter inside the workstation. oDo not open lid nor use the USB connectors in hazardous locations. oDo not expose to direct sunlight or UV light source. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
NOTE:
oWhen used with the display HMIDM6421, HMIDM6521, HMIDM7421, or HMIDM7521, the Magelis Box iPC Optimized, Universal or Performance can be used in Class I Division 2 hazardous (classified) locations.
oWhen using the DC power supply, the Display Adapter (HMIDADP11) with the display can be classified hazardous locations.
oWhen using the AC power supply, the Display Adapter, the display, and the AC power supply adapter for 100 W (HMIYMMAC1) are certified for use in Class I Division 2 hazardous (classified) locations.
|
LOSS OF CONTROL |
oThe designer of any control scheme must consider the potential failure modes of control paths and, for certain critical control functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are emergency stop and overtravel stop. oSeparate or redundant control paths must be provided for critical control functions. oSystem control paths may include communication links. Consideration must be given to the implications of unanticipated transmission delays or failures of the link.(1) oEach implementation of a Magelis Industrial PC must be individually and thoroughly tested for proper operation before being placed into service. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
(1) For additional information, refer to NEMA ICS 1.1 (latest edition), "Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control" and to NEMA ICS 7.1 (latest edition),”Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable-Speed Drive Systems” or other applicable standards in your location.
The display 4:3 12” and 4:3 15” have a touch screen with analog-resistive touch technology that may operate abnormally when two or more points are touched.
|
UNINTENDED EQUIPMENT OPERATION |
Do not touch two or more points on display. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
The display W12”, W15”, W19” and W22” multi-touch have a touch screen with projected capacitive touch technology that may operate abnormally when the surface is wet.
|
LOSS OF CONTROL |
oDo not touch the touch screen area during Operating System startup. oDo not operate when the touch screen surface is wet. oIf the touch screen surface is wet, remove any excessive water with a soft cloth before operation. oMake sure to use only the authorized grounding configurations shown in the grounding procedure. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
NOTE:
oThe touch control is disabled in case of abnormal touch (like water) for a few seconds to avoid accidental touch. The normal touch function will be recovered a few seconds after removing the abnormal touch condition.
oDo not touch the touch screen area during Operating System startup since "touch panel firmware" initializes automatically when Windows starts up.
NOTE:
The following characteristics are specific to the LCD and are considered normal behavior:
oLCD screen may show unevenness in the brightness of certain images or may appear different when seen from outside the specified viewing angle. Extended shadows, or cross-talk, may also appear on the sides of screen images.
oLCD screen pixels may contain black and white-colored spots and color display may seem to have changed over time.
oWhen the same image is displayed on the screen for a long period, an after-image may appear when the image is changed. If this happens, turn off the unit, wait 10 seconds, and then restart it.
oThe panel brightness may decrease when used for a long time in an environment continuously filled with inert gas. To prevent deterioration of panel brightness, regularly ventilate the panel.
NOTE: The Magelis Box iPC Optimized, Universal or Performance is a configurable device and is not based on a real-time operating system. Changes to the software and settings of the following must be considered new implementations as described in the previous warning messages. Examples of such changes include:
oSystem BIOS
oSystem monitor
oOperating system
oInstalled hardware
oInstalled software
NOTE: Windows Operating System includes security protection for USB devices. When using some USB devices, the system may experience technical issues. The resolution is available here: http://www.schneider-electric.com/en/faqs/index?page=content&id=FA290340&actp=search&viewlocale=en_US&searchid=1469171130324#__highlight
|
UNINTENDED EQUIPMENT OPERATION |
Use only Schneider Electric software with the devices described in this manual. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |