This section contains information regarding the operation of the . Qualified personnel working with the axis must read and observe this information. The axis was built in compliance with the recognized technical safety regulations.
The axis is intended to be installed in a machine or assembled with other components to build up a machine or system.
Provide for Protective Measures
Before installing the axis, provide appropriate protective devices in compliance with local and national standards. Do not commission components without appropriate protective devices. After installation, commissioning, or repair, test the protective devices used.
Perform a risk evaluation concerning the specific use before operating the axis and take appropriate security measures.
|
UNINTENDED EQUIPMENT OPERATION |
Ensure that a risk assessment is conducted and respected according to EN/ISO 12100 during the design of your machine. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
If circumstances occur that affect the safety or cause changes to the operating behavior of the axis, then immediately shut down the axis and contact your local Schneider Electric service representative.
Use only the accessories and mounting parts specified in the documentation and only third-party devices or components that have been expressly approved by Schneider Electric. Only modify the axis in the manner intended and described in this documentation, and other documentation concerning any other associated equipment.
|
UNINTENDED EQUIPMENT OPERATION |
oUpdate your application program every time you change the physical hardware configuration. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
The axis is not suitable for the manipulation of living organisms or explosive materials, nor is it suitable for impact movement.
The components must not be used in the following environments:
oHazardous (explosive) atmospheres
oMobile, movable, or floating systems
oLife support systems
oDomestic appliances
oUnderground
oHighly saline environments (refer to Technical Data for materials used)
oEnvironments with increased radioactive radiation
oWash-down areas (food or pharmaceutical industry)
oHigh-hygienic areas
oVacuum
The axis has been designed to operate outside of any hazardous location. Only install the axis in zones known to be free of a hazardous atmosphere.
|
POTENTIAL FOR EXPLOSION |
Install and use this equipment in non-hazardous locations only. |
Failure to follow these instructions will result in death or serious injury. |
Installation and Operating Conditions
Only use the components in accordance with the installation and operating conditions described in this documentation. The operating conditions at the installation location must be inspected and maintained in accordance with the required technical data (performance data and ambient conditions). Commissioning is prohibited until the usable machine or system in which the axis is installed is in accordance to the applicable local regulations and standards.
The forces and torques (Fy, Fz, Mx, Mz, My) are calculated for an expected service life of . This period
oshortens with increasing load and dynamic or
oextends with decreasing load and dynamic.
For an application-specific calculation of the service life of the axis, refer to Service Life.
Compatibility with Foreign Substances
It is impossible to follow up on all further developments of all substances such as lubricants, cleaning agents, or solvents. Therefore, you must perform a compatibility test before using new substances.