Convert an ATV32 device configuration to an ATV320 device configuration by using the SoMove configuration software. As a prerequisite, the configuration file (*.psx) corresponding to the ATV32 device to convert is required.
The migration of ATV32 to ATV320 devices is performed in three steps that are described in this document:
|
Step |
Action |
|---|---|
|
1 |
Generating the ATV32 configuration file (*.psx). |
|
2 |
Converting the ATV32 device configuration to an ATV320 device configuration. |
|
3 |
Importing the converted ATV320 project into EcoStruxure Machine Expert. |
The following procedure describes how to generate the ATV32 configuration file (*.psx) directly from the device by using SoMove V2.6 or later:
|
Step |
Action |
Result |
|---|---|---|
|
1 |
Launch SoMove. |
The SoMove start page opens. |
|
2 |
Execute the command . |
– |
|
3 |
In the dialog box, select the connection settings that correspond to the ATV32 device you want to convert. For further information, refer to the SoMove online help. |
– |
|
4 |
Click . |
The dialog box is closed. |
|
5 |
Execute the command from the SoMove start page. |
– |
|
6 |
Select a file to save the SoMove project. |
– |
|
7 |
Select the file type . |
– |
|
8 |
Click . |
The upload process starts. |
To convert an ATV32 to an ATV320 device, perform the following steps:
|
Step |
Action |
Result |
|---|---|---|
|
1 |
Launch SoMove. |
The SoMove start page opens. |
|
2 |
Execute the command . |
The dialog box opens. |
|
3 |
Select the ATV32 configuration file (*.psx) that you want to convert, and click . |
The dialog box opens. |
|
4 |
Select from the list and click . |
The dialog box opens. |
|
5 |
Select the option or according to your requirements. |
The compatible , , , and parameters are displayed for the selected option. |
|
6 |
Click . |
The message is displayed. |
|
7 |
Click to close the message. |
The converted ATV320 project opens. |
To import the converted ATV320 device configuration into EcoStruxure Machine Expert, perform the following steps:
|
Step |
Action |
Result |
|---|---|---|
|
1 |
Launch SoMove. |
The SoMove start page opens. |
|
2 |
Execute the command . |
– |
|
3 |
In the dialog box, select the connection settings that correspond to the ATV320 device you want to update. For further information, refer to the SoMove online help. |
– |
|
4 |
Click . |
The dialog box is closed. |
|
5 |
Execute the command . |
– |
|
6 |
Close SoMove. |
– |
|
7 |
Open your EcoStruxure Machine Expert project, and select in the . |
– |
|
8 |
Upload the device configuration for the ATV320 device. For more information, refer to the Device Type Manager (DTM) - User Guide. |
– |