Description of Error Messages

Description

If monitoring functions of the drive detect an error, the drive generates an error message. Each error message is identified by an error code.

The following information is available for each error message:

  • Error code

  • Error class

  • Description of error

  • Possible causes

  • Possible remedies

Range of Error Messages

The table below summarizes the error codes classified by range.

Error code

Range

E 1xxx

General

E 2xxx

Overcurrent

E 3xxx

Voltage

E 4xxx

Temperature

E 5xxx

Hardware

E 6xxx

Software

E 7xxx

Interface, wiring

E 8xxx

Fieldbus

E Axxx

Motor movement

E Bxxx

Communication

Error Class of Error Messages

The error messages are classified according to the following error classes:

Error class

State transition(1)

Error response

Resetting the error message

0

-

No interruption of the movement

Function “Fault Reset”

1

T11

Stop movement with “Quick Stop”

Function “Fault Reset”

2

T13, T14

Stop movement with “Quick Stop” and disable the power stage when the motor has come to a standstill

Function “Fault Reset”

3

T13, T14

Disable the power stage immediately without stopping the movement first

Function “Fault Reset”

4

T13, T14

Disable the power stage immediately without stopping the movement first

Power cycle

(1) See section Operating States.