IF_Configuration - Cartesian2Ax (Method)

Overview

Type:

Method

Available as of:

V1.0.0.0

This chapter provides information on:

Task

Configuring a biaxial Cartesian robot.

Description

With the method Cartesian2Ax(...), the robot can be configured as a Cartesian robot with two degrees of freedom.

The axes A and B move along the coordinate axes of the Cartesian coordinate system according to the configuration i_etPlane.

NOTE: If a method to configure a transformation was already called up successfully (q_etDiag = GD.ET_Diag.Ok AND q_etDiagExt = ET_DiagExt.Ok), then it is not possible to overwrite the parameterization by calling up another method for configuring a transformation.

Interface

Input

Data type

Description

i_ifDriveA

SystemConfigurationItf.IF_Drive

Drive of axis A.

i_ifDriveB

SystemConfigurationItf.IF_Drive

Drive of axis B.

i_etPlane

ROB.ET_WorkingPlane

Specification in which working plane the robot is processing.

Output

Data type

Description

q_etDiag

GD.ET_Diag

General library-independent statement on the diagnostic.

A value not equal to ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = ET_Diag.Ok ->Status message

q_etDiag <> ET_Diag.Ok -> Diagnostic message

q_sMsg

STRING[80]

Event-triggered message that gives additional information on the diagnostic state.

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Ok

0

Ok

ExecutionAborted

ConfigurationAlreadyCompleted

154

The configuration is already completed.

ExecutionAborted

TransformationAlreadyConfigured

171

The transformation is already configured.

InputParameterInvalid

DriveAAlreadyInUse

164

The drive A is already in use.

InputParameterInvalid

DriveAInvalid

167

The drive A is invalid.

InputParameterInvalid

DriveBAlreadyInUse

165

The drive B is already in use.

InputParameterInvalid

DriveBInvalid

168

The drive B is invalid.

InputParameterInvalid

PlaneInvalid

170

The working plane is invalid.

ConfigurationAlreadyCompleted

Enumeration name:

ConfigurationAlreadyCompleted

Enumeration value:

154

Description:

The configuration is already completed.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The configuration of the robot has already been completed. The method ConfigDone(...) has already been called up successfully.

Ensure that no transformation configuration method, for example Delta3Ax(...) or AddAuxAx(...), is called after the configuration has been completed.

DriveAAlreadyInUse

Enumeration name:

DriveAAlreadyInUse

Enumeration value:

164

Description:

The drive A is already in use.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The drive transferred at the input i_ifDriveA is already configured in the robot and cannot be used again.

Ensure that no drive is assigned to the robot more than once, and correct if necessary.

DriveAInvalid

Enumeration name:

DriveAInvalid

Enumeration value:

167

Description:

The drive A is invalid.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The drive transferred at the input i_ifDriveA is invalid.

At the input i_ifDriveA, a valid drive must be transferred.

DriveBAlreadyInUse

Enumeration name:

DriveBAlreadyInUse

Enumeration value:

165

Description:

The drive B is already in use.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The drive transferred at the input i_ifDriveB is already configured in the robot and cannot be used again.

Ensure that no drive is assigned to the robot more than once, and correct if necessary.

DriveBInvalid

Enumeration name:

DriveBInvalid

Enumeration value:

168

Description:

The drive B is invalid.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The drive transferred at the input i_ifDriveB is invalid.

At the input i_ifDriveB, a valid drive must be transferred.

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Ok

The configuration of the robot transformation was successful.

PlaneInvalid

Enumeration name:

PlaneInvalid

Enumeration value:

170

Description:

The working plane is invalid.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The value transferred at the input i_etPlane is invalid.

At the input i_etPlane, a value contained in ROB.ET_WorkingPlane must be transferred.

TransformationAlreadyConfigured

Enumeration name:

TransformationAlreadyConfigured

Enumeration value:

171

Description:

The transformation is already configured.

Issue

Cause

Solution

The configuration of the robot transformation was not successful.

The configuration of the robot transformation has already been completed successfully.

Ensure that a configuration for a transformation is only called once.