InverterEnable

General

Type

AD

Devices supporting the parameter

Lexium LXM52 Drive, Lexium LXM52 Linear Drive,

Lexium LXM62 Drive, Lexium LXM62 Linear Drive,

Lexium ILM62 Drive Module,

Lexium LXM62 Power Supply

Traceable

Yes

Functional Description

The parameter indicates the status of the InverterEnable signal.

Value

Data type

Meaning

off / 0

BOOL

The lock-out tag-out sequence is enabled (Safe Torque Off).

on / 1

BOOL

The lock-out tag-out sequence is disabled.

The following figure indicates the influence of ControllerEnable, TorqueEnable, and InverterEnable on the power stage release of the servo amplifier.

NOTE: In the Lexium 52, the InverterEnable signal is determined from the two parameters STO_A and STO_B, according to the following formula:

InverterEnable := NOT (STO_A OR STO_B).